Skip to search boxSkip to navigationSkip to main content

The use of metal sublaminar wires in modern growth-guidance scoliosis surgery: A report of 4 cases and literature review

  • R. Bogie(corresponding author)
    ,
  • ,
  • S. N. Koole
    ,
  • L. W. van Rhijn
    ,
  • P. C. Willems
*Corresponding author for this work
  • Sint Anna Hospital
    ,
  • Maastricht University Medical Center
Output:
Contribution to journal
Review article
Academic
Peer-review

Open access

Information

Output type

Output:
Contribution to journal
Review article
Academic
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 182-188 (7 pages)

Journal (Volume, Issue Number)

International Journal of Spine Surgery (Volume 14, Issue 2)

Publication milestones

  • Published - 2020

Publication status

Published - 2020

ISSN

2211-4599

Abstract

<p>Background: To avoid early fusion and allow residual growth of the spine in early onset scoliosis (EOS) treatment, growth-guided scoliosis surgery can be performed. Four patients with EOS are presented in which a growth-guidance instrumentation is used with sliding titanium (Ti) sublaminar cables. Residual growth of the spine can be preserved using metal sublaminar wiring; however, several drawbacks of this technique and type of material are illustrated. Methods: Four patients with progressive neuromuscular scoliosis were treated with a posterior stabilization. A fusionless growth-guidance instrumentation was used consisting of a combination of lumbar pedicle screws and sliding Ti sublaminar cables along cobalt chrome rods. Results: In 2 cases, the described growth-guidance technique provided sufficient stability and correction of the curvature with preservation of growth. In 2 patients, the instrumentation failed due to upper thoracic sublaminar wire breakage. The ongoing abrasion of the rod-wire interface caused severe metallosis. In these cases, a debridement and revision surgery was performed with partial fusion of the spine. Conclusions: Growth-guidance techniques with sliding metal sublaminar wires seem to be a valuable solution for the preservation of spinal growth in EOS surgery. High curvatures, however, have a higher chance of failure and demand for more corrective strength and support of the instrumentation. The use of metal sublaminar wires in a ''sliding'' instrumentation can lead to early breakage and metallosis. Level of Evidence: 4, case series. Clinical Relevance: Surgeons should be aware of possible complications associated with the use of metal laminar wires in spinal fusion and growth-guidance scoliosis surgery. The implementation of materials containing higher fatigue strength and lower friction properties (eg, UHMWPE wires) may avoid these potential complication risks.</p>

Bibliographical Note

Publisher Copyright: © International Society for the Advancement of Spine Surgery

Metrics

Metrics

SciVal
FWCI
0.28
SciVal
Author count
5
SciVal
Paper percentile
41
SciVal
citations
9
Scopus
citations
9

PlumX, opens in new tab

Citation count
9
Captures
14