The transfer impedance of cables with a nearby return conductor and a noncentral inner conductor
- ,
- ,
- P.C.T. Laan, van der
Output:
Contribution to journal
Article
Academic
Peer-reviewInformation
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 301-306 (6 pages)Journal (Volume, Issue Number)
IEEE Transactions on Electromagnetic Compatibility (Volume 37, Issue 2)Publication milestones
- Published - 1995
Publication status
Published - 1995
ISSN
0018-9375Abstract
The transfer impedance Z/sub t/ of a cable is often assumed to be a characteristic of the shield only. We investigate the limits of this assumption by calculations and measurements. The first test cable was formed by a solid copper tube (ldquoshieldrdquo) and a wire inside; several positions, also non-central, were chosen for the wire. The common mode current (between 10 Hz and 100 kHz) through the tube had as return path a single wire, which was placed at several positions, near and at some distance from the shield. A second cable with a braided shield was tested as well. The results show that both the differential mode and the common mode circuit have to be carefully defined for a particular Z/sub t/. Varying either circuit may alter Z/sub t/ drastically. Consequently, the Z/sub t/ of a particular cable measured in a triaxial setup, is a characteristic of that setup and cannot always be used in another setup as in for instance cable bundles