Synthetic jet cooling part II: Experimental results of an acoustic dipole cooler
- C.J.M. Lasance,
- ,
- O. Ouweltjes
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOpen access
Information
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 26-32Publication milestones
- Published - 2008
Publication status
Published - 2008
Place of publication
PiscatawayPublisher
Institute of Electrical and Electronics Engineers, United StatesISBN (Print)
978-1-4244-2123-7Host publication title
2008 Twenty-Fourth Annual IEEE Semiconductor Thermal Measurement and Management Symposium : [SEMI-THERM 24] ; San Jose, CA, 16 - 20 March 2008Host publication editors
- P. Wesling
- K. Erickson
Abstract
The paper discusses experimental results for a typical embodiment of synthetic jet cooling technology: an acoustic dipole cooler comprised of a standard loudspeaker in a housing provided with two pipes. A transient measurement set up is used to measure the average heat transfer coefficient based on cooling a 5*5 cm2 metal plate. Heat transfer and noise results are presented for a range of frequencies, pipe lengths and diameters. The results are compared with a standard 60*60 mm fan. It is concluded that, at least for the cases studied, the synthetic jet is superior on all fronts: heat transfer performance, noise level and dissipated power
Documents and Links
Final published version, 278.3 KB
Metrics
Metrics
SciVal
FWCI
0.81
SciVal
Author count
3
SciVal
Paper percentile
67
SciVal
citations
23
Download statistics
Download count
347
Scopus
citations
23
PlumX, opens in new tab
Captures
22
Citation count
23