Skip to search boxSkip to navigationSkip to main content

Segmentation of multiple heart cavities in 3-D transesophageal ultrasound images

  • A. Haak
    ,
  • G. Vegas-Sanchez-Ferrero
    ,
  • H.W. Mulder
    ,
  • B. Ren
    ,
  • H.A. Kirisli
    ,
  • C. Metz
Output:
Contribution to journal
Article
Academic
Peer-review

Information

Output type

Output:
Contribution to journal
Article
Academic
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 1179-1189

Journal (Volume, Issue Number)

IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control (Volume 62, Issue 6)

Publication milestones

  • Published - 06/2015

Publication status

Published - 06/2015

ISSN

0885-3010

Abstract

Three-dimensional transesophageal echocardiography (TEE) is an excellent modality for real-time visualization of the heart and monitoring of interventions. To improve the usability of 3-D TEE for intervention monitoring and catheter guidance, automated segmentation is desired. However, 3-D TEE segmentation is still a challenging task due to the complex anatomy with multiple cavities, the limited TEE field of view, and typical ultrasound artifacts. We propose to segment all cavities within the TEE view with a multi-cavity active shape model (ASM) in conjunction with a tissue/blood classification based on a gamma mixture model (GMM). 3-D TEE image data of twenty patients were acquired with a Philips X7-2t matrix TEE probe. Tissue probability maps were estimated by a two-class (blood/tissue) GMM. A statistical shape model containing the left ventricle, right ventricle, left atrium, right atrium, and aorta was derived from computed tomography angiography (CTA) segmentations by principal component analysis. ASMs of the whole heart and individual cavities were generated and consecutively fitted to tissue probability maps. First, an average whole-heart model was aligned with the 3-D TEE based on three manually indicated anatomical landmarks. Second, pose and shape of the whole-heart ASM were fitted by a weighted update scheme excluding parts outside of the image sector. Third, pose and shape of ASM for individual heart cavities were initialized by the previous whole heart ASM and updated in a regularized manner to fit the tissue probability maps. The ASM segmentations were validated against manual outlines by two observers and CTA derived segmentations.

Metrics

Metrics

Scopus
citations
18
SciVal
FWCI
1.59
SciVal
Author count
12
SciVal
Paper percentile
82
SciVal
citations
18
Download statistics
Download count
4

PlumX, opens in new tab

Captures
48
Citation count
19