Skip to search boxSkip to navigationSkip to main content

Pulsed-Current Operation Enhances H2O2 Production on a Boron-Doped Diamond Mesh Anode in a Zero-Gap PEM Electrolyzer

  • Adam Vass
    ,
  • Maximilian Göltz
    ,
  • Hanadi Ghanem
    ,
  • Stefan Rosiwal
    ,
  • Tanja Franken
    ,
  • Regina Palkovits
*Corresponding author for this work
  • University of Twente
    ,
  • University of Erlangen-Nuremberg
    ,
  • RWTH Aachen University
    ,
  • Research Centre Julich (FZJ)
    ,
  • Max-Planck-Institut für Bioanorganische Chemie
    ,
  • DIFFER Dutch Institute for Fundamental Energy Research
Output:
Contribution to journal
Article
Academic
Peer-review

Open access

Information

Output type

Output:
Contribution to journal
Article
Academic
Peer-review

Original language

English

Article number

e202401947

Journal (Volume, Issue Number)

ChemSusChem (Volume 18, Issue 9)

Publication milestones

  • E-pub ahead of print - 16/01/2025
  • Published - 05/05/2025

Publication status

Published - 05/05/2025

ISSN

1864-5631

Funding Details

This research was financially supported by the Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) under the framework of the Electrochemical Conversion and Materials (ECCM) program, through projects ECCM.TT.ECCM.005, ECCM.TT.ECCM.004 and KICH1.ED04.20.025. In addition, the authors acknowledge the financial support by the German Research Foundation (DFG) within the frameworks of the project (DFG-grant AL2479/1-1). The authors acknowledge the contribution of VSparticle and Fumatech GMBH. The authors would also like to acknowledge S. Harsha and M.T. Abudukade (University of Twente) for Pt sputter deposition and fabrication of the cathode gas diffusion electrodes. RP thanks the Cluster of Excellence Fuel Science Center (EXC 2186, ID: 390919832) by the Excellence Initiative of the German federal and state governments to promote science and research at German universities for funding. This research was financially supported by the Nederlandse Organisatie voor Wetenschappelijk Onderzoek (NWO) under the framework of the Electrochemical Conversion and Materials (ECCM) program, through projects ECCM.TT.ECCM.005, ECCM.TT.ECCM.004 and KICH1.ED04.20.025. In addition, the authors acknowledge the financial support by the German Research Foundation (DFG) within the frameworks of the project (DFG\u2010grant AL2479/1\u20101). The authors acknowledge the contribution of VSparticle and Fumatech GMBH. The authors would also like to acknowledge S. Harsha and M.T. Abudukade (University of Twente) for Pt sputter deposition and fabrication of the cathode gas diffusion electrodes. RP thanks the Cluster of Excellence Fuel Science Center (EXC 2186, ID: 390919832) by the Excellence Initiative of the German federal and state governments to promote science and research at German universities for funding.
FunderFunding numbers
NWO
ECCM.TT.ECCM.005, ECCM.TT.ECCM.004, KICH1.ED04.20.025

Abstract

A niobium (Nb) mesh electrode was coated with boron-doped diamond (BDD) using chemical vapor deposition in a custom-built hot-filament reactor. The BDD-functionalized mesh was tested in a zero-gap electrolysis configuration and evaluated for the anodic formation of H2O2 by selective oxidation of water, including the analysis of the effects on Faradaic efficiency towards H2O2 (FEH2O2) induced by pulsed electrolysis. A low electrolyte flow rate (V⋅anolyte) was found to result in a relatively high concentration of H2O2 in single-pass electrolysis experiments. Regarding pulsed electrolysis, we show an optimal ratio of on-time to off-time to obtain the highest concentration of H2O2. Off-times that are “too short” result in decreased FEH2O2, whereas “too long” off-times dilute the product in the electrolyte stream. Using our electrolyzer setup with an anodic pulse of 2 s with 4 s intervals, and a V⋅anolyte of 0.75 cm3 min−1, resulted in the best performance. This adjustment increased the FEH2O2 by 70 % compared to constant current electrolysis, at industrially relevant current densities (150 mA cm−2). Fine tuning of BDD morphology, flow patterns, and anolyte composition might further increase the performance of zero-gap electrolyzers in pulsed operation modes.

Bibliographical Note

Publisher Copyright: © 2024 The Author(s). ChemSusChem published by Wiley-VCH GmbH.

Metrics

Metrics

SciVal
citations
6
Scopus
citations
6
SciVal
FWCI
0.87
SciVal
Author count
10
SciVal
Paper percentile
68

PlumX, opens in new tab

Citation count
6
Captures
7