Optimal kernel sizes for 4D image reconstruction using normalized convolution from sparse fast-rotating transesophageal 2D ultrasound images
- A. Haak,
- S. Klein,
- Gerard van Burken,
- N. Jong, de,
- A.F.W. Steen, van der,
- Johannes G. Bosch
- Erasmus University Medical Center,
- Research not related to TU/e workplace (outside TU/e employment)
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewInformation
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 703-706Publication milestones
- Published - 2012
Publication status
Published - 2012
Place of publication
PiscatawayPublisher
Institute of Electrical and Electronics Engineers, United StatesISBN (Print)
978-1-4673-4561-3Host publication title
2012 IEEE International Ultrasonics Symposium, IUS 2012, 7 October 2012 through 10 October 2012, DresdenAbstract
A transesophageal echocardiography (TEE) micro-probe is suitable for monitoring long minimally invasive interventions in the heart, because it is well tolerated by patients. To visualize complex 3D structures of the beating heart, a 4D-image reconstruction derived from irregularly and sparsely sampled 2D images is needed. We previously showed that normalized convolution (NC) with optimized kernels performs better than nearest-neighbor or linear interpolation. In order to use NC for image reconstructions we need to be able to predict optimal kernel sizes. We therefore present an advanced optimization scheme, and estimate optimal NC kernel sizes for five different patient-data sets. From the optimization results we derive a model for estimating optimal NC kernel sizes. As ground truth (GT), we used five full-volume 4D TEE patient scans, acquired with the X7-2t matrix transducer. To simulate 2D data acquisition, the GT datasets were sliced at random rotation angles and at random normalized cardiac phases. Data sets containing 400, 600, 900, 1350, and 1800 2D images were created for all patients, producing a total of 25 data sets. A 2D Gaussian function was used as NC kernel, and optimal kernel sizes were obtained with a quasi-Newton optimizer. A power law model was fitted to the optimal kernels estimated. We conclude that optimal kernel sizes for NC can be successfully predicted by a model at the cost of a relatively small increase in the reconstruction error. © 2012 IEEE.
Documents and Links
Metrics
Metrics
Download statistics
Download count
1
SciVal
Author count
8
SciVal
Paper percentile
35
PlumX, opens in new tab
Captures
12
