Optical Single Sideband Signal Reconstruction Based on Time-Domain Iteration
- Wei Wang,
- Dongdong Zou,
- Zibin Li,
- Qi Sui,
- Zizheng Cao,
- Chao Lu
- Sun Yat-Sen University,
- Southern Marine Science and Engineering Guangdong Laboratory,
- ,
- Hong Kong Polytechnic University
Output:
Contribution to journal
Article
Academic
Peer-reviewOpen access
Information
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishArticle number
9320540Pages from-to (Number of pages)
Pages 2319-2326 (8 pages)Journal (Volume, Issue Number)
Journal of Lightwave Technology (Volume 39, Issue 8)Publication milestones
- Accepted/In press - 2021
- Published - 15/04/2021
Publication status
Published - 15/04/2021
ISSN
0733-8724Abstract
<p>Due to its low cost, simple architecture and robustness to fiber dispersion, single sideband (SSB) transmission with direct detection (DD) system is an attractive solution for 80-km inter data center interconnect (DCI). However, it will suffer performance penalty caused by the signal-to-signal beating interference (SSBI). Kramers-Kronig (KK) receiver has been extensively investigated for SSBI elimination by reconstructing the SSB signal. The nonlinear operations in KK algorithm require up-sampling to cope with spectral broadening, which results in high complexity for practical application. Optical signal phase retrieval method based on the minimum phase signal has also been investigated for SSB signal recovery, in which the SSB and DC-Value properties are iteratively imposed on the amplitude signal in frequency domain. In this paper, we propose a low complexity iterative algorithm for minimum phase signal recovery without up-sampling in time domain. Finite impulse response (FIR) filter is applied to iteratively generate the SSB signal and update the phase component. Based on the proposed scheme, the transmission of 30GHz SSB 16-QAM discrete multitone (DMT) signal over 80km single mode fiber (SMF) is successfully demonstrated with the bit error rate (BER) below the hard-decision forward error correction (HD-FEC) threshold of <formula><tex>$3.8 × 10^{-3}$</tex></formula>. The experimental results show that, the BER performance of KK scheme with up-sampling factor of 2, frequency-domain iteration scheme and our proposed scheme is almost the same. However, compared with the KK scheme, the proposed method can save the numbers of adders and multipliers by the factors of 29 and 7, while the factors are 5.5 and 4 comparing to the frequency-domain iteration scheme.</p>
Documents and Links
Metrics
Metrics
SciVal
citations
13
SciVal
FWCI
1.06
SciVal
Author count
8
SciVal
Paper percentile
73
Scopus
citations
13
Download statistics
Download count
230
PlumX, opens in new tab
Captures
11
Citation count
13