Non-image forming effects of illuminance level: exploring parallel effects on physiological arousal and task performance
- L.M. Huiberts,
- ,
Output:
Contribution to journal
Article
Academic
Peer-reviewOpen access
Information
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 129-139 (11 pages)Journal (Volume, Issue Number)
Physiology & Behavior (Volume 164)Publication milestones
- Published - 2016
Publication status
Published - 2016
ISSN
0031-9384Abstract
<p style="margin: 0px 0px 9px; padding: 0px; border: 0px currentColor; border-image: none; color: rgb(46, 46, 46); font-family: Arial, Helvetica, "Lucida Sans Unicode", "Microsoft Sans Serif", "Segoe UI Symbol", STIXGeneral, "Cambria Math", "Arial Unicode MS", sans-serif; font-size: 16px; word-spacing: -0.15ex; vertical-align: baseline;">This study investigated diurnal non-image forming (NIF) effects of illuminance level on physiological arousal in parallel to NIF effects on vigilance and working memory performance. We employed a counterbalanced within-subjects design in which thirty-nine participants (mean age = 21.2; <em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">SD</em> = 2.1; 11 male) completed three 90-min sessions (165 vs. 600 lx vs. 1700 lx at eye level) either in the morning (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">N</em> = 18) or afternoon (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">N</em> = 21). During each session, participants completed four measurement blocks (incl. one baseline block) each consisting of a 10-min Psychomotor Vigilance Task (PVT) and a Backwards Digit-Span Task (BDST) including easy trials (4–6 digits) and difficult trials (7–8 digits). Heart rate (HR), skin conductance level (SCL) and systolic blood pressure (SBP) were measured continuously.</p><p style="margin: 0px 0px 9px; padding: 0px; border: 0px currentColor; border-image: none; color: rgb(46, 46, 46); font-family: Arial, Helvetica, "Lucida Sans Unicode", "Microsoft Sans Serif", "Segoe UI Symbol", STIXGeneral, "Cambria Math", "Arial Unicode MS", sans-serif; font-size: 16px; word-spacing: -0.15ex; vertical-align: baseline;">The results revealed significant improvements in performance on the BDST difficult trials under 1700 lx vs. 165 lx (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">p</em> = 0.01), while illuminance level did not affect performance on the PVT and BDST easy trials. Illuminance level impacted HR and SCL, but not SBP. In the afternoon sessions, HR was significantly higher under 1700 lx vs. 165 lx during PVT performance (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">p</em> = 0.05), while during BDST performance, HR was only slightly higher under 600 vs. 165 lx (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">p</em> = 0.06). SCL was significantly higher under 1700 lx vs. 165 lx during performance on BDST easy trials (<em style="margin: 0px; padding: 0px; border: 0px currentColor; border-image: none; vertical-align: baseline;">p</em> = 0.02) and showed similar, but nonsignificant trends during the PVT and BDST difficult trials. Although both physiology and performance were affected by illuminance level, no consistent pattern emerged with respect to parallel changes in physiology and performance. Rather, physiology and performance seemed to be affected independently, via unique pathways.</p>
Documents and Links
Submitted manuscript, 586.34 KB
Metrics
Metrics
Download statistics
Download count
1013
SciVal
citations
106
SciVal
FWCI
2.32
SciVal
Author count
3
SciVal
Paper percentile
89
Scopus
citations
106
PlumX, opens in new tab
Citation count
107
Captures
165
