Skip to search boxSkip to navigationSkip to main content

Myoglobin and troponin concentrations are increased in early stage deep tissue injury

  • W.A. Traa(corresponding author)(Corresponding author)
    ,
  • G.J. Strijkers
    ,
  • D.L. Bader
    ,
  • C.W.J. Oomens
*Corresponding author for this work
Output:
Contribution to journal
Article
Academic
Peer-review

Open access

Information

Output type

Output:
Contribution to journal
Article
Academic
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 50-57 (8 pages)

Journal (Volume, Issue Number)

Journal of the Mechanical Behavior of Biomedical Materials (Volume 92)

Publication milestones

  • Published - 01/04/2019

Publication status

Published - 01/04/2019

ISSN

1751-6161

Funding Details

This work was supported by the Dutch Technology Foundation (STW) under grant 12398 . STW is part of the Netherlands Organisation for Scientific Research (NWO) and is partly funded by the Ministry of Economic Affairs . The authors gratefully acknowledge David Veraart, Leonie Niessen, Carlijn Tijsen-van Helvert, Roy Lucassen and Marije Janssen for their biotechnical assistance.

Abstract

Pressure-induced deep tissue injury is a form of pressure ulcer which is difficult to detect and diagnose at an early stage, before the wound has severely progressed and becomes visible at the skin surface. At the present time, no such detection technique is available. To test the hypothesis that muscle damage biomarkers can be indicative of the development of deep tissue injury after sustained mechanical loading, an indentation test was performed for 2 h on the tibialis anterior muscle of rats. Myoglobin and troponin were analysed in blood plasma and urine over a period of 5 days. The damage as detected by the biomarkers was compared to damage as observed with T 2 MRI to validate the response. We found that myoglobin and troponin levels in blood increased due to the damage. Myoglobin was also increased in urine. The amount of damage observed with MRI immediately after loading had a strong correlation with the maximal biomarker levels: troponin in blood r s = 0.94; myoglobin in blood r s = 0.75; and myoglobin in urine r s = 0.57. This study suggests that muscle damage markers measured in blood and urine could serve as early diagnosis for pressure induced deep tissue injury.

Metrics

Metrics

Scopus
citations
17
Download statistics
Download count
244
SciVal
FWCI
0.65
SciVal
Author count
4
SciVal
Paper percentile
60
SciVal
citations
17

PlumX, opens in new tab

Captures
30
Citation count
17