Modeling, identification and control of a metrological Atomic Force Microscope with a 3DOF stage
- R.J.E. Merry,
- M. Uyanik,
- K.R. Koops,
- ,
- M.G.A. van Veghel,
- ,
- NMI VSL B.V.
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewInformation
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 2716-2721 (6 pages)Publication milestones
- Published - 2008
Publication status
Published - 2008
Place of publication
PiscatawayPublisher
Institute of Electrical and Electronics Engineers, United StatesISBN (Print)
978-1-4244-2078-0Host publication title
Proceedings of the 2008 American Control Conference (ACC2008)Related Event
Title
2008 American Control Conference (ACC 2008)
Description
2008 American Control Conference
Event type
ConferenceDegree of recognition
International eventDate
11/06/2008 - 13/06/2008Location
Westin Seattle HotelSeattle, WAUnited States
Abstract
Atomic Force Microscopes (AFMs) are widely used for the investigation of samples at nanometer scale. In this paper, we present the modeling, the identification and the control of a metrological AFM. The metrological AFM is used for the calibration of transfer standards for commercial AFMs. Therefore, the focus of the presented work is on scanning accuracy rather than on scanning speed. The contribution of this paper is the combination of 3 degree-of-freedom (DOF) control, including position feedforward, with an AFM with fixed cantilever and a piezo-stack driven stage. The amount of coupling between all DOFs is assessed by a non-parametric MIMO identification of the AFM. Since the dynamics appear to be decoupled in the frequency range of interest, feedback controllers are designed using loopshaping techniques for each DOF separately. Position feedforward is added to the stage in x and y direction, which improves the tracking performance by a factor two. The controlled stage is able to track scanning profiles within the sensor bound of 5 nm. With the proposed control method, the metrological AFM can produce images of the transfer standards with a sensor bound of 2 nm. Furthermore, real-time imaging of the sample is possible without the need for a-posteriori image correction. Finally, it is shown that the proposed control method almost completely compensates the hysteresis in the system.
Documents and Links
Metrics
Metrics
SciVal
FWCI
0.95
SciVal
Author count
6
SciVal
Paper percentile
70
SciVal
citations
4
Scopus
citations
4
PlumX, opens in new tab
Citation count
4
Captures
12
