Skip to search boxSkip to navigationSkip to main content

Modeling, identification and control of a metrological Atomic Force Microscope with a 3DOF stage

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Information

Output type

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 2716-2721 (6 pages)

Publication milestones

  • Published - 2008

Publication status

Published - 2008

Place of publication

Piscataway

Publisher

Institute of Electrical and Electronics Engineers, United States
978-1-4244-2078-0

Host publication title

Proceedings of the 2008 American Control Conference (ACC2008)

Related Event

Title

2008 American Control Conference (ACC 2008)

Description

2008 American Control Conference

Event type

Conference

Degree of recognition

International event

Date

11/06/2008 - 13/06/2008

Location

Westin Seattle HotelSeattle, WAUnited States

Abstract

Atomic Force Microscopes (AFMs) are widely used for the investigation of samples at nanometer scale. In this paper, we present the modeling, the identification and the control of a metrological AFM. The metrological AFM is used for the calibration of transfer standards for commercial AFMs. Therefore, the focus of the presented work is on scanning accuracy rather than on scanning speed. The contribution of this paper is the combination of 3 degree-of-freedom (DOF) control, including position feedforward, with an AFM with fixed cantilever and a piezo-stack driven stage. The amount of coupling between all DOFs is assessed by a non-parametric MIMO identification of the AFM. Since the dynamics appear to be decoupled in the frequency range of interest, feedback controllers are designed using loopshaping techniques for each DOF separately. Position feedforward is added to the stage in x and y direction, which improves the tracking performance by a factor two. The controlled stage is able to track scanning profiles within the sensor bound of 5 nm. With the proposed control method, the metrological AFM can produce images of the transfer standards with a sensor bound of 2 nm. Furthermore, real-time imaging of the sample is possible without the need for a-posteriori image correction. Finally, it is shown that the proposed control method almost completely compensates the hysteresis in the system.