Skip to search boxSkip to navigationSkip to main content

Measurement of cardio-respiratory dynamics during sleep arousals with a suprasternal pressure sensor

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Open access

Information

Output type

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Original language

English

Article number

10596779

Publication milestones

  • Published - 29/07/2024

Publication status

Published - 29/07/2024

Publisher

Institute of Electrical and Electronics Engineers, United States

ISBN (Electronic)

979-8-3503-0799-3

Host publication title

M2024 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2024

Funding Details

This work was performed within the IMPULS framework of the Eindhoven MedTech Innovation Center (e/MTIC, incorporating Eindhoven University of Technology, Philips Research, and Sleep Medicine Center Kempenhaeghe), including a PPS-supplement from Dutch Ministry of Economic Affairs and Climate Policy. Additional support by STW/IWT in the context of the OSA+ project (No. 14619).

Related Event

Title

2024 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2024

Event type

Conference

Degree of recognition

International event

Date

26/06/2024 - 28/06/2024

Location

High Tech CampusEindhovenNetherlands

Abstract

Sleep-disordered breathing disorders, such as ob-structive sleep apnea (OSA), are increasingly prevalent in the general population. Their main characteristic is the recurrence of apneas and hypopneas during sleep, which can cause hypoxia and arousals, degrading overall sleep quality. Fragmented sleep has profound effects on health and quality of life, in both the short (daytime sleepiness, irritability) and long term (increased cardiovascular risk, metabolic distress). The recommended pro-cedure to detect sleep apnea disorders is a polysomnography, with a broad set of sensors covering every aspect of sleep. If polysomnography is unfeasible, home sleep apnea test devices are available for screening purposes and initial diagnoses. However, they employ a reduced set of sensors, which limits the amount of information available, for example misdetecting the time awake, or detecting events through proxy measurements, such as oxygen desaturations instead of apneas. To mitigate the issue, suprasternal notch pressure (SSP) sensors can provide a reliable measure of both respiratory effort and cardiac activity, opening the way to more direct measurements of sleep apnea events and associated heart rate surges. Here, we assess the possibility of characterizing arousals using solely the response of SSP signals to cortical arousals caused by various physiological events. Preliminary results show that distinct patterns of respiratory effort and heart rate are visible in the components of the SSP signal during arousals.

Metrics

Metrics

Download statistics
Download count
100
SciVal
citations
1
SciVal
FWCI
0.45
SciVal
Author count
5
SciVal
Paper percentile
49
Scopus
citations
1

PlumX, opens in new tab

Citation count
1
Captures
5