Skip to search boxSkip to navigationSkip to main content

Improving microstructural integrity, interstitial fluid, and blood microcirculation images from multi-b-value diffusion MRI using physics-informed neural networks in cerebrovascular disease

  • Paulien H.M. Voorter
    ,
  • Walter H. Backes
    ,
  • Oliver J. Gurney-Champion
    ,
  • Sau May Wong
    ,
  • Julie Staals
    ,
  • Robert J. van Oostenbrugge
*Corresponding author for this work
Output:
Contribution to journal
Article
Academic
Peer-review

Open access

Information

Output type

Output:
Contribution to journal
Article
Academic
Peer-review

Original language

English

Pages from-to (Number of pages)

Pages 1657-1671 (15 pages)

Journal (Volume, Issue Number)

Magnetic Resonance in Medicine (Volume 90, Issue 4)

Publication milestones

  • Published - 10/2023

Publication status

Published - 10/2023

ISSN

0740-3194

Abstract

Purpose: To obtain better microstructural integrity, interstitial fluid, and microvascular images from multi-b-value diffusion MRI data by using a physics-informed neural network (PINN) fitting approach. Methods: Test–retest whole-brain inversion recovery diffusion-weighted images with multiple b-values (IVIM: intravoxel incoherent motion) were acquired on separate days for 16 patients with cerebrovascular disease on a 3.0T MRI system. The performance of the PINN three-component IVIM (3C-IVIM) model fitting approach was compared with conventional fitting approaches (i.e., non-negative least squares and two-step least squares) in terms of (1) parameter map quality, (2) test–retest repeatability, and (3) voxel-wise accuracy. Using the in vivo data, the parameter map quality was assessed by the parameter contrast-to-noise ratio (PCNR) between normal-appearing white matter and white matter hyperintensities, and test–retest repeatability was expressed by the coefficient of variation (CV) and intraclass correlation coefficient (ICC). The voxel-wise accuracy of the 3C-IVIM parameters was determined by 10,000 computer simulations mimicking our in vivo data. Differences in PCNR and CV values obtained with the PINN approach versus conventional fitting approaches were assessed using paired Wilcoxon signed-rank tests. Results: The PINN-derived 3C-IVIM parameter maps were of higher quality and more repeatable than those of conventional fitting approaches, while also achieving higher voxel-wise accuracy. Conclusion: Physics-informed neural networks enable robust voxel-wise estimation of three diffusion components from the diffusion-weighted signal. The repeatable and high-quality biological parameter maps generated with PINNs allow for visual evaluation of pathophysiological processes in cerebrovascular disease.

Metrics

Metrics

SciVal
FWCI
2.75
SciVal
Author count
9
SciVal
Paper percentile
92
SciVal
citations
24
SciVal
Top percentile
10
Scopus
citations
24
Download statistics
Download count
88

PlumX, opens in new tab

Citation count
24
Captures
24