Skip to search boxSkip to navigationSkip to main content

Dose distribution as outcome predictor for Gamma Knife radiosurgery on vestibular schwannoma

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Information

Output type

Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-review

Original language

English

Article number

109504C

Publication milestones

  • Published - 13/03/2019

Publication status

Published - 13/03/2019

Place of publication

Hoboken

Publisher

SPIE, United States

Publication series

  • Publisher name: SPIE
    Publication series name: Proceedings of SPIE
    ISSN (Print): 1605-7422
    Volume: 10950

ISBN (Electronic)

9781510625471

Host publication title

Medical Imaging 2019: Computer-Aided Diagnosis

Host publication editors

  • Kensaku Mori
  • Horst K. Hahn

Related Event

Title

SPIE Medical Imaging 2019

Event type

Conference

Degree of recognition

International event

Date

16/02/2019 - 21/02/2019

Location

San DiegoUnited States

Abstract

Vestibular schwannomas are benign brain tumors that can be treated radiosurgically with the Gamma Knife in order to stop tumor progression. However, in some cases tumor progression is not stopped and treatment is deemed a failure. At present, the reason for these failed treatments is unknown. Clinical factors and MRI characteristics have been considered as prognostic factors. Another confounder in the success of treatment is the treatment planning itself. It is thought to be very uniformly planned, even though dose distributions among treatment plans are highly inhomogeneous. This paper explores the predictive value of these dose distributions for the treatment outcome. We compute homogeneity indices (HI) and three-dimensional histogram-of-oriented gradients (3D-HOG) and employ support vector machine (SVM) paired with principal component analysis (PCA) for classification. In a clinical dataset, consisting of 20 tumors that showed treatment failure and 20 tumors showing treatment success, we discover that the correlation of the HI values with the treatment outcome presents no statistical evidence of an association (52:5% accuracy employing linear SVM and no statistical significant difference with t-tests), whereas the 3D-HOG features concerning the dose distribution do present correlations to the treatment outcome, suggesting the influence of the treatment on the outcome itself (77:5% accuracy employing linear SVM and PCA). These findings can provide a basis for refining towards personalized treatments and prediction of treatment efficiency. However, larger datasets are needed for more extensive analysis.

Metrics

Metrics

SciVal
citations
1
Scopus
citations
1
SciVal
Author count
6
SciVal
Paper percentile
25

PlumX, opens in new tab

Captures
9
Citation count
1