Dose distribution as outcome predictor for Gamma Knife radiosurgery on vestibular schwannoma
- ,
- ,
- ,
- H.B. Verheul,
- Sieger Leenstra,
- ,
- ,
- ,
- ,
- Elisabeth-TweeSteden Ziekenhuis
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewInformation
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOriginal language
EnglishArticle number
109504CPublication milestones
- Published - 13/03/2019
Publication status
Published - 13/03/2019
Place of publication
HobokenPublisher
SPIE, United StatesPublication series
- Publisher name: SPIE
Publication series name: Proceedings of SPIE
ISSN (Print): 1605-7422
Volume: 10950
ISBN (Electronic)
9781510625471Host publication title
Medical Imaging 2019: Computer-Aided DiagnosisHost publication editors
- Kensaku Mori
- Horst K. Hahn
Related Event
Title
SPIE Medical Imaging 2019
Event type
ConferenceDegree of recognition
International eventDate
16/02/2019 - 21/02/2019Location
San DiegoUnited States
Abstract
Vestibular schwannomas are benign brain tumors that can be treated radiosurgically with the Gamma Knife in order to stop tumor progression. However, in some cases tumor progression is not stopped and treatment is deemed a failure. At present, the reason for these failed treatments is unknown. Clinical factors and MRI characteristics have been considered as prognostic factors. Another confounder in the success of treatment is the treatment planning itself. It is thought to be very uniformly planned, even though dose distributions among treatment plans are highly inhomogeneous. This paper explores the predictive value of these dose distributions for the treatment outcome. We compute homogeneity indices (HI) and three-dimensional histogram-of-oriented gradients (3D-HOG) and employ support vector machine (SVM) paired with principal component analysis (PCA) for classification. In a clinical dataset, consisting of 20 tumors that showed treatment failure and 20 tumors showing treatment success, we discover that the correlation of the HI values with the treatment outcome presents no statistical evidence of an association (52:5% accuracy employing linear SVM and no statistical significant difference with t-tests), whereas the 3D-HOG features concerning the dose distribution do present correlations to the treatment outcome, suggesting the influence of the treatment on the outcome itself (77:5% accuracy employing linear SVM and PCA). These findings can provide a basis for refining towards personalized treatments and prediction of treatment efficiency. However, larger datasets are needed for more extensive analysis.
Documents and Links
Metrics
Metrics
SciVal
citations
1
Scopus
citations
1
SciVal
Author count
6
SciVal
Paper percentile
25
PlumX, opens in new tab
Captures
9
Citation count
1