An improved Hilbert–Huang method for analysis of time-varying waveforms in power quality
- N. Senroy,
- S. Suryanarayanan,
- P.F. Ribeiro
Output:
Contribution to journal
Article
Academic
Peer-reviewInformation
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 1843-1850 (8 pages)Journal (Volume, Issue Number)
IEEE Transactions on Power SystemsPublication milestones
- Published - 2007
Publication status
Published - 2007
ISSN
0885-8950Abstract
The Hilbert-Huang method is presented with modifications, for time-frequency analysis of distorted power quality signals. The empirical mode decomposition (EMD) is enhanced with masking signals based on fast Fourier transform (FFT), for separating frequencies that lie within an octave. Further, the instantaneous frequency and amplitude of the constituent modes obtained by Hilbert spectral analysis are improved by demodulation. The method shows promising time-frequency-magnitude localization capabilities for distorted power quality signals. The performance of the new technique is compared with that of another multiresolution analysis tool, the S-transform-a phase corrected wavelet transform. Analysis on actual measurements of transformer inrush current from an existing laboratory setup is used to demonstrate this technique.
Documents and Links
Metrics
Metrics
Download statistics
Download count
1
Scopus
citations
234
SciVal
FWCI
6.59
SciVal
Author count
3
SciVal
Paper percentile
98
SciVal
Top percentile
5
SciVal
citations
234
PlumX, opens in new tab
Captures
74
Citation count
234