Active vibration isolation of metrology frames; a modal decoupled control design
- ,
- K. Graaff, de,
- J.C. van der Toorn
Output:
Contribution to journal
Article
Academic
Peer-reviewInformation
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 223-233Journal (Volume, Issue Number)
Journal of Vibration and Acoustics (Volume 127, Issue 3)Publication milestones
- Published - 2005
Publication status
Published - 2005
ISSN
1048-9002Abstract
For a six degree-of-freedom active vibration isolation system, a control strategy based on modal decoupling is proposed. This has the advantage of controlling the modal directions on a centralized single-input single-output basis. As a consequence, stability and performance can be imposed in each of the modal directions separately. An experimental demonstration is given using a dummy metrology frame. That is, a 1600 kg payload mass supported by three combined pneumatic and Lorentz controlled isolators. With this setup, two unstable modal directions resulting from a high center of gravity are stabilized without compromising performance in any of the remaining directions. In fact, performance in the remaining directions is enhanced using manual loop shaping.