A transoesophageal echocardiographic image acquisition protocol for wide-view fusion of three-dimensional datasets to support atrial fibrillation catheter ablation
- B. Ren,
- H.W. (Harriët) Mulder,
- A. Haak,
- M. Stralen, van,
- T. Szili-Torok,
- Research not related to TU/e workplace (outside TU/e employment),
- Erasmus University Medical Center
Output:
Contribution to journal
Article
Academic
Peer-reviewInformation
Output type
Output:
Contribution to journal
Article
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 21-26 (6 pages)Journal (Volume, Issue Number)
Journal of Interventional Cardiac Electrophysiology (Volume 37, Issue 1)Publication milestones
- Published - 2013
Publication status
Published - 2013
ISSN
1383-875XAbstract
Purpose: The aim of this paper is to propose a transoesophageal echocardiography (TOE) image acquisition protocol which provides a systematic manner of acquiring a minimal number of overlapping 3D TOE datasets allowing the reconstruction of a wide 3D view of the left atrium (LA) with anatomical landmarks that are important for atrial fibrillation catheter ablation. Methods: In eight cardiac surgical patients, 3D TOE datasets were acquired with a six-step protocol. In the protocol, step 1 aims to acquire the central view of the mitral valve (MV), aortic valve (AV) and left atrial appendage (LAA). Step 2 was developed to acquire the left pulmonary veins (PVs) and step 3 to acquire the right PVs. Steps 4, 5 and 6 were developed to create a sufficient overlap between different datasets. 3D TOE datasets were registered and fused manually in end diastole. Results: The image acquisition protocol was feasible in all patients. In the fused 3D dataset, a wide 3D view of the LA is shown, and left and right PVs could be seen simultaneously. The LAA, MV, AV and fossa ovalis (FO) were visualised clearly in the 3D TOE datasets. The PV ostia, which are located at the edges of the 3D datasets, suffered more from the artefact of echo loss. The volume overlaps between neighbouring TOE datasets were 50-75 %. Conclusion: The major part of the LA anatomy incorporating the PVs, LAA, MV, AV and FO as important anatomical landmarks can be reconstructed by registering and fusing 3D datasets acquired with the six-step TOE image acquisition protocol. © 2012 Springer Science+Business Media New York.
Documents and Links
Metrics
Metrics
SciVal
FWCI
0.37
SciVal
Author count
8
SciVal
Paper percentile
51
SciVal
citations
7
Scopus
citations
7
PlumX, opens in new tab
Captures
32
Citation count
7
