A review study of fetal circulatory models to develop a digital twin of a fetus in a perinatal life support system
Output:
Contribution to journal
Review article
Academic
Peer-reviewOpen access
Information
Output type
Output:
Contribution to journal
Review article
Academic
Peer-reviewOriginal language
EnglishArticle number
915846Journal (Volume, Issue Number)
Frontiers in Pediatrics (Volume 10)Publication milestones
- Published - 21/09/2022
Publication status
Published - 21/09/2022
ISSN
2296-2360Funding Details
This project has received funding from the European Union's Horizon 2020 research and innovation programme under grant agreement No. 863087.
FunderFunding number
European Union's Horizon 2020 - Research and Innovation Framework Programme
863087
Abstract
<p>Background: Preterm birth is the main cause of neonatal deaths with increasing mortality and morbidity rates with decreasing GA at time of birth. Currently, premature infants are treated in neonatal intensive care units to support further development. However, the organs of, especially, extremely premature infants (born before 28 weeks of GA) are not mature enough to function optimally outside the womb. This is seen as the main cause of the high morbidity and mortality rates in this group. A liquid-filled incubator, a so-called PLS system, could potentially improve these numbers for extremely premature infants, since this system is designed to mimic the environment of the natural womb. To support the development and implementation of such a complex system and to interpret vital signals of the fetus during a PLS system operation, a digital twin is proposed. This mathematical model is connected with a manikin representing the digital and physical twin of the real-life PLS system. Before developing a digital twin of a fetus in a PLS system, its functional and technical requirements are defined and existing mathematical models are evaluated.</p><p>Method and results: This review summarizes existing 0D and 1D fetal circulatory models that potentially could be (partly) adopted for integration in a digital twin of a fetus in a PLS system based on predefined requirements. The 0D models typically describe hemodynamics and/or oxygen transport during specific events, such as the transition from fetus to neonate. Furthermore, these models can be used to find hemodynamic differences between healthy and pathological physiological states. Rather than giving a global description of an entire cardiovascular system, some studies focus on specific organs or vessels. In order to analyze pressure and flow wave profiles in the cardiovascular system, transmission line or 1D models are used. As for now, these models do not include oxygen transport.</p><p>Conclusion: This study shows that none of the models identified in literature meet all the requirements relevant for a digital twin of a fetus in a PLS system. Nevertheless, it does show the potential to develop this digital twin by integrating (parts) of models into a single model.</p>
Bibliographical Note
Copyright © 2022 van Willigen, van der Hout-van der Jagt, Huberts and van de Vosse.
Documents and Links
Metrics
Metrics
SciVal
FWCI
1.18
SciVal
Author count
4
SciVal
Paper percentile
75
SciVal
citations
19
Download statistics
Download count
280
Scopus
citations
19
PlumX, opens in new tab
Captures
51
Citation count
20