A Modelica based computational model for evaluating a renewable district heating system
- F.F.M. Soons,
- J.I. Torrens Galdiz,
- ,
- R.A.M. de Schrevel
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOpen access
Information
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Peer-reviewOriginal language
EnglishPages from-to (Number of pages)
Pages 1-16Publication milestones
- Published - 2014
Publication status
Published - 2014
Host publication title
Proceedings of the 9th International Conference on System Simulation in Buildings, December 10-12, 2014, Liege, BelgiumRelated Event
Title
9th International Conference on System Simulation in Buildings (SSB 2014), December 10-12, 2014, Liege, Belgium
Event type
ConferenceDate
10/12/2014 - 12/12/2014Location
LiegeBelgium
Abstract
District heating (DH) systems are considered a viable method for mitigating long-term climate change effects, through reduction of CO2 emissions, their high conversion efficiencies and their ability to be integrated with renewable energy sources (RES). The current evolution towards sustainable DH, e.g. integration of RES, results in increased complexity and diversity during the early-design phase. In the early-design phase of DH systems a feasibility study is conducted to assess if the economic and environmental factors of the project meet the given requirements. This assessment is generally conducted with traditional district heating computational models (DHCM), utilizing a simulation language which limits the evaluation of sustainable DH systems in terms of flexibility and comprehensibility. The need for an alternative language capable of effectively modeling DH systems with integrated RES led to the use of Modelica, which offers improved flexibility, reusability as well as hierarchical and multi-domain modeling. This paper presents a case study, for the evaluation of a new DHCM analyzing its modeling capabilities and system performance, of an educational campus formed by eight institutional buildings connected to a centralized power plant, holding among others a biomass gasifier and a gas boiler. For an optimum utilization of the biomass gasifier, two power plant configurations are assessed: a biomass gasifier system with and without thermal energy storage (TES). The system performance evaluation indicates a significant increase in the utilization of the biomass gasifier with 8.2% (353 hours) compared to results obtained from the traditional DHCM. This deviation is due to a more accurate consideration of the DH thermal capacity and the space heating demand. Furthermore, the models in this DHCM enable assessments of the impact of building retrofits or climate change scenarios. Thus, the increased modeling capabilities and system performance demonstrate that this new DHCM is suitable and beneficial for early-design feasibility studies of innovative RES integrated DH systems.
Documents and Links
Final author version , 682.57 KB
Metrics
Metrics
Download statistics
Download count
1159
UN SDGs
In 2015, UN member states agreed to 17 global Sustainable Development Goals (SDGs) to end poverty, protect the planet and ensure prosperity for all. This output contributes to the following SDG(s):
- SDG 7 Affordable and Clean Energy
- SDG 13 Climate Action