A Model for the prediction of Sound Levels within a Symphonic Orchestra based on measured Sound Strength
- ,
- ,
- L.C.J. Luxemburg, van
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Open access
Information
Output type
Output:
Chapter in Book/Report/Conference proceeding
Conference contribution
Academic
Original language
EnglishPages from-to (Number of pages)
Pages 1-6Publication milestones
- Published - 2011
Publication status
Published - 2011
Place of publication
MadridPublisher
EAAISBN (Print)
97-84-694-1520-7Host publication title
Proceedings of Forum Acusticum 2011 AalborgRelated Event
Title
6th Forum Acusticum 2011 (FA 2011), 27 June - 01 July 2011, Aalborg, Denmark
Description
Forum Acusticum
Event type
ConferenceDate
27/06/2011 - 01/07/2011Location
AalborgDenmark
Abstract
Members and directors of symphonic orchestras are concerned about the noise levels musicians are exposed to and their ease of playing ensemble. The results of many research has shown that the noise levels within an orchestra can be high. Also, research has shown that the sound level will vary between different musicians playing different instruments and musical pieces or musicians being positioned differently on various stages. Aspects of influence on sound levels can be musically based: the piece and its interpretation by the orchestra; or acoustically: the impact of the stage and hall acoustics. However, the contribution of each instrument and each acoustical aspect on the total sound level cannot be determined from sound level measurements.
Therefore, a sound level prediction model is proposed based on the sound strength G and the early to late reflection ratio LQ7-40. For every combination of two orchestra instruments, the direct, early reflected and late reflected sound energy transfer is calculated. In the direct sound transfer, the directivity and sound power of the instrument and the attenuation of the orchestra are taken into account. The early and late reflected sound energy is based on the sound power and on measured values of G and LQ7-40. From the individual sound level contributions, the total sound level and balance between different instruments and different acoustical aspects can be calculated. First results show that the model gives insight in the sound levels within a symphonic orchestra from a health as well as a musical point of view.
Documents and Links
Final published version, 305.1 KB
Metrics
Metrics
Download statistics
Download count
124