Samenvatting
Normative standard methods for validating the performance of reverberation chambers are based on a mixture of field anisotropy and field inhomogeneity contributions. We investigate alternative metrics that enable both aspects of field nonuniformity to be separated. The results are particularly relevant to EUTs that do not fit inside the working volume, including floor-standing equipment subjected to statistical field inhomogeneity caused by boundary conditions, and electrically large EUTs with considerable variations in the location-to-location field statistics, even within the working volume.
Originele taal-2 | Engels |
---|---|
Titel | 2016 International Symposium on Electromagnetic Compatibility, EMC EUROPE - Proceedings, 5-9 September 2016, Wroclaw, Poland |
Plaats van productie | Piscataway |
Uitgeverij | Institute of Electrical and Electronics Engineers |
Pagina's | 205-210 |
Aantal pagina's | 6 |
ISBN van elektronische versie | 978-1-5090-1416-3 |
ISBN van geprinte versie | 978-1-5090-1417-0 |
DOI's | |
Status | Gepubliceerd - 8 nov. 2016 |
Evenement | 2016 International Symposium on Electromagnetic Compatibility, EMC EUROPE 2016 - Wroclaw, Polen Duur: 5 sep. 2016 → 9 sep. 2016 |
Congres
Congres | 2016 International Symposium on Electromagnetic Compatibility, EMC EUROPE 2016 |
---|---|
Verkorte titel | EMC EUROPE 2016 |
Land/Regio | Polen |
Stad | Wroclaw |
Periode | 5/09/16 → 9/09/16 |