Objective To evaluate preferences from patients and users on 3 uterine monitoring techniques, during labor. Study Design Women in term labor were simultaneously monitored with the intrauterine pressure catheter, the external tocodynamometer, and the electrohysterograph. Postpartum, these women filled out a questionnaire evaluating their preferences and important aspects. Nurses completed a questionnaire evaluating users' preferences. Results Of all 52 participating women, 80.8% preferred the electrohysterograph, 17.3% the intrauterine pressure catheter and 1.9% the external tocodynamometer. For these women, the electrohysterograph scored best regarding application and presence during labor (p < 0.001). Most important aspects were least likely to harm and least discomfort. Of 57 nurses, 40.4% preferred the electrohysterograph, 35.1% the external tocodynamometer, and 24.6% had no preference, or replied that their preference is subject to situation and patient. Conclusion Patients prefer the electrohysterograph over the external tocodynamometer and the intrauterine pressure catheter, while healthcare providers report ambiguous results.

TaalEngels
Pagina'se184-e191
Aantal pagina's8
TijdschriftAJP Reports
Volume8
Nummer van het tijdschrift3
DOI's
StatusGepubliceerd - 1 jul 2018

Vingerafdruk

Uterine Monitoring
Catheters
Personnel
Pressure
Monitoring
Nurses
Patient Preference
Health Personnel
Postpartum Period
Surveys and Questionnaires

Trefwoorden

    Citeer dit

    @article{bd6e08ab76f2460e9cbc95fb4d092458,
    title = "Uterine monitoring techniques from patients' and users' perspectives",
    abstract = "Objective To evaluate preferences from patients and users on 3 uterine monitoring techniques, during labor. Study Design Women in term labor were simultaneously monitored with the intrauterine pressure catheter, the external tocodynamometer, and the electrohysterograph. Postpartum, these women filled out a questionnaire evaluating their preferences and important aspects. Nurses completed a questionnaire evaluating users' preferences. Results Of all 52 participating women, 80.8{\%} preferred the electrohysterograph, 17.3{\%} the intrauterine pressure catheter and 1.9{\%} the external tocodynamometer. For these women, the electrohysterograph scored best regarding application and presence during labor (p < 0.001). Most important aspects were least likely to harm and least discomfort. Of 57 nurses, 40.4{\%} preferred the electrohysterograph, 35.1{\%} the external tocodynamometer, and 24.6{\%} had no preference, or replied that their preference is subject to situation and patient. Conclusion Patients prefer the electrohysterograph over the external tocodynamometer and the intrauterine pressure catheter, while healthcare providers report ambiguous results.",
    keywords = "cardiotocography (MeSH), electrohysterograph, external tocodynamometer, intrauterine pressure catheter, patient preference (MeSH), user preference, uterine contraction (MeSH), uterine monitoring (MeSH)",
    author = "Thijssen, {Kirsten M.J.} and Vlemminx, {Marion W.C.} and Westerhuis, {Michelle E.M.H.} and Dieleman, {Jeanne P.} and {van der Hout-van der Jagt}, {M. Beatrijs} and Oei, {S. Guid}",
    year = "2018",
    month = "7",
    day = "1",
    doi = "10.1055/s-0038-1669409",
    language = "English",
    volume = "8",
    pages = "e184--e191",
    journal = "AJP Reports",
    issn = "2157-6998",
    publisher = "Georg Thieme Verlag KG",
    number = "3",

    }

    Uterine monitoring techniques from patients' and users' perspectives. / Thijssen, Kirsten M.J.; Vlemminx, Marion W.C.; Westerhuis, Michelle E.M.H.; Dieleman, Jeanne P.; van der Hout-van der Jagt, M. Beatrijs; Oei, S. Guid.

    In: AJP Reports, Vol. 8, Nr. 3, 01.07.2018, blz. e184-e191.

    Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

    TY - JOUR

    T1 - Uterine monitoring techniques from patients' and users' perspectives

    AU - Thijssen,Kirsten M.J.

    AU - Vlemminx,Marion W.C.

    AU - Westerhuis,Michelle E.M.H.

    AU - Dieleman,Jeanne P.

    AU - van der Hout-van der Jagt,M. Beatrijs

    AU - Oei,S. Guid

    PY - 2018/7/1

    Y1 - 2018/7/1

    N2 - Objective To evaluate preferences from patients and users on 3 uterine monitoring techniques, during labor. Study Design Women in term labor were simultaneously monitored with the intrauterine pressure catheter, the external tocodynamometer, and the electrohysterograph. Postpartum, these women filled out a questionnaire evaluating their preferences and important aspects. Nurses completed a questionnaire evaluating users' preferences. Results Of all 52 participating women, 80.8% preferred the electrohysterograph, 17.3% the intrauterine pressure catheter and 1.9% the external tocodynamometer. For these women, the electrohysterograph scored best regarding application and presence during labor (p < 0.001). Most important aspects were least likely to harm and least discomfort. Of 57 nurses, 40.4% preferred the electrohysterograph, 35.1% the external tocodynamometer, and 24.6% had no preference, or replied that their preference is subject to situation and patient. Conclusion Patients prefer the electrohysterograph over the external tocodynamometer and the intrauterine pressure catheter, while healthcare providers report ambiguous results.

    AB - Objective To evaluate preferences from patients and users on 3 uterine monitoring techniques, during labor. Study Design Women in term labor were simultaneously monitored with the intrauterine pressure catheter, the external tocodynamometer, and the electrohysterograph. Postpartum, these women filled out a questionnaire evaluating their preferences and important aspects. Nurses completed a questionnaire evaluating users' preferences. Results Of all 52 participating women, 80.8% preferred the electrohysterograph, 17.3% the intrauterine pressure catheter and 1.9% the external tocodynamometer. For these women, the electrohysterograph scored best regarding application and presence during labor (p < 0.001). Most important aspects were least likely to harm and least discomfort. Of 57 nurses, 40.4% preferred the electrohysterograph, 35.1% the external tocodynamometer, and 24.6% had no preference, or replied that their preference is subject to situation and patient. Conclusion Patients prefer the electrohysterograph over the external tocodynamometer and the intrauterine pressure catheter, while healthcare providers report ambiguous results.

    KW - cardiotocography (MeSH)

    KW - electrohysterograph

    KW - external tocodynamometer

    KW - intrauterine pressure catheter

    KW - patient preference (MeSH)

    KW - user preference

    KW - uterine contraction (MeSH)

    KW - uterine monitoring (MeSH)

    UR - http://www.scopus.com/inward/record.url?scp=85053445001&partnerID=8YFLogxK

    U2 - 10.1055/s-0038-1669409

    DO - 10.1055/s-0038-1669409

    M3 - Article

    VL - 8

    SP - e184-e191

    JO - AJP Reports

    T2 - AJP Reports

    JF - AJP Reports

    SN - 2157-6998

    IS - 3

    ER -