Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

Using a high resolution magnetic sector mass spectrometer for fast analysis of transient reaction processes in automotive catalytic converters

  • J.M.A. Harmsen
  • , T. Bijvoets
  • , J.H.B.J. Hoebink
  • , T. Hachiya
  • , J. Bassett
  • , A.D. Brooker
  • , J.C. Schouten

    Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

    Samenvatting

    A high-resolution magnetic sector mass spectrometer has been developed and used for transient kinetic measurements on reactions that are important for automotive exhaust gas catalysis. This instrument allows separation of the isobaric masses of CO and N2 as well as CO2 and N2O, which are separately monitored in time at a sampling rate of 48 Hz. The time resolution is sufficient to determine individual kinetic rate parameters for reactions under transient conditions. A description of the experimental set-up as well as the software used is given. The results are illustrated by the catalytic reduction of NO by CO. To the best knowledge of the authors, this is the first application of a magnetic sector mass spectrometer for kinetic research under dynamic operation conditions.
    Originele taal-2Engels
    Pagina's (van-tot)957-964
    TijdschriftRapid Communications in Mass Spectrometry
    Volume16
    Nummer van het tijdschrift10
    DOI's
    StatusGepubliceerd - 2002

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Using a high resolution magnetic sector mass spectrometer for fast analysis of transient reaction processes in automotive catalytic converters'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit