Samenvatting
The influence of a DC electric field on CH4/air flat flame characteristics was experimentally investigated. To understand the mechanism of the electric field influence on a flame a number of experiments were conducted: measurements of the flame burning velocities using the heat flux method, OH LIF measurements and measurements
of the flame emission spectra. Two alternative explanations were proposed for an apparent increase in the burning rate induced by the electric field with positive polarity.
Originele taal-2 | Engels |
---|---|
Titel | Proc. of the 4th European Combustion Meeting |
Plaats van productie | Austria, Vienna |
Uitgeverij | Combustion Institute |
Status | Gepubliceerd - 2009 |
Evenement | 4th European Combustion Meeting (ECM 2009), April 14-17, 2009, Vienna, Austria - Vienna, Oostenrijk Duur: 14 apr. 2009 → 17 apr. 2009 |
Congres
Congres | 4th European Combustion Meeting (ECM 2009), April 14-17, 2009, Vienna, Austria |
---|---|
Verkorte titel | ECM 2009 |
Land/Regio | Oostenrijk |
Stad | Vienna |
Periode | 14/04/09 → 17/04/09 |
Ander | 4th European Combustion Meeting (ECM 2009), 14-17 april 2009, Vienna, Austria |