The energy efficient use of an air handling unit for balancing an aquifer thermal energy storage system

Basar Bozkaya (Corresponding author), Wim Zeiler

Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

Uittreksel

Aquifer thermal energy storage (ATES) systems, which utilize underground water for heat exchange with buildings, have been proven to be an excellent heating and cooling source. However, their operation is limited by strict regulations, one of which is the requirement for balance in the amount of heat transfer to the ground. Systems are highly exposed to cooling dominated loads, which results in excess heat injection into the ground. Commonly, an air handling unit is utilized to expel heat from the ATES system. This is known as the direct compensation (DC) method. In this study, an alternative approach that uses night ventilation (NV) was presented as a promising solution in combination with DC. Night ventilation can be used to decrease the cooling load and by using NV the system can avoid excess heat injection into the ground. The DC method was combined with NV under various control settings and compared with a system that uses only DC. The optimal operational setting between DC and NV operation was determined based on simulating a case study building. The study determined that the energy performance of the system can be improved by 16% by optimally adapting NV to the DC method.

TaalEngels
Pagina's1932-1942
Aantal pagina's11
TijdschriftRenewable Energy
Volume146
DOI's
StatusGepubliceerd - 1 feb 2020

Vingerafdruk

Thermal energy
Aquifers
Energy storage
Ventilation
Air
Cooling
Compensation and Redress
Groundwater
Heat transfer
Heating
Hot Temperature

Trefwoorden

    Citeer dit

    @article{5c788149795c4593b89576fd4112c1ad,
    title = "The energy efficient use of an air handling unit for balancing an aquifer thermal energy storage system",
    abstract = "Aquifer thermal energy storage (ATES) systems, which utilize underground water for heat exchange with buildings, have been proven to be an excellent heating and cooling source. However, their operation is limited by strict regulations, one of which is the requirement for balance in the amount of heat transfer to the ground. Systems are highly exposed to cooling dominated loads, which results in excess heat injection into the ground. Commonly, an air handling unit is utilized to expel heat from the ATES system. This is known as the direct compensation (DC) method. In this study, an alternative approach that uses night ventilation (NV) was presented as a promising solution in combination with DC. Night ventilation can be used to decrease the cooling load and by using NV the system can avoid excess heat injection into the ground. The DC method was combined with NV under various control settings and compared with a system that uses only DC. The optimal operational setting between DC and NV operation was determined based on simulating a case study building. The study determined that the energy performance of the system can be improved by 16{\%} by optimally adapting NV to the DC method.",
    keywords = "Air handling unit, Aquifer thermal, Aquifer thermal energy storage, Control of ATES, Thermal balance",
    author = "Basar Bozkaya and Wim Zeiler",
    year = "2020",
    month = "2",
    day = "1",
    doi = "10.1016/j.renene.2019.07.111",
    language = "English",
    volume = "146",
    pages = "1932--1942",
    journal = "Renewable Energy",
    issn = "0960-1481",
    publisher = "Elsevier",

    }

    The energy efficient use of an air handling unit for balancing an aquifer thermal energy storage system. / Bozkaya, Basar (Corresponding author); Zeiler, Wim.

    In: Renewable Energy, Vol. 146, 01.02.2020, blz. 1932-1942.

    Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

    TY - JOUR

    T1 - The energy efficient use of an air handling unit for balancing an aquifer thermal energy storage system

    AU - Bozkaya,Basar

    AU - Zeiler,Wim

    PY - 2020/2/1

    Y1 - 2020/2/1

    N2 - Aquifer thermal energy storage (ATES) systems, which utilize underground water for heat exchange with buildings, have been proven to be an excellent heating and cooling source. However, their operation is limited by strict regulations, one of which is the requirement for balance in the amount of heat transfer to the ground. Systems are highly exposed to cooling dominated loads, which results in excess heat injection into the ground. Commonly, an air handling unit is utilized to expel heat from the ATES system. This is known as the direct compensation (DC) method. In this study, an alternative approach that uses night ventilation (NV) was presented as a promising solution in combination with DC. Night ventilation can be used to decrease the cooling load and by using NV the system can avoid excess heat injection into the ground. The DC method was combined with NV under various control settings and compared with a system that uses only DC. The optimal operational setting between DC and NV operation was determined based on simulating a case study building. The study determined that the energy performance of the system can be improved by 16% by optimally adapting NV to the DC method.

    AB - Aquifer thermal energy storage (ATES) systems, which utilize underground water for heat exchange with buildings, have been proven to be an excellent heating and cooling source. However, their operation is limited by strict regulations, one of which is the requirement for balance in the amount of heat transfer to the ground. Systems are highly exposed to cooling dominated loads, which results in excess heat injection into the ground. Commonly, an air handling unit is utilized to expel heat from the ATES system. This is known as the direct compensation (DC) method. In this study, an alternative approach that uses night ventilation (NV) was presented as a promising solution in combination with DC. Night ventilation can be used to decrease the cooling load and by using NV the system can avoid excess heat injection into the ground. The DC method was combined with NV under various control settings and compared with a system that uses only DC. The optimal operational setting between DC and NV operation was determined based on simulating a case study building. The study determined that the energy performance of the system can be improved by 16% by optimally adapting NV to the DC method.

    KW - Air handling unit

    KW - Aquifer thermal

    KW - Aquifer thermal energy storage

    KW - Control of ATES

    KW - Thermal balance

    UR - http://www.scopus.com/inward/record.url?scp=85070570353&partnerID=8YFLogxK

    U2 - 10.1016/j.renene.2019.07.111

    DO - 10.1016/j.renene.2019.07.111

    M3 - Article

    VL - 146

    SP - 1932

    EP - 1942

    JO - Renewable Energy

    T2 - Renewable Energy

    JF - Renewable Energy

    SN - 0960-1481

    ER -