Battery energy storage (BES) can provide many grid services, such as power flow management to reduce distribution grid overloading. It is desirable to minimise BES storage capacities to reduce investment costs. However, it is not always clear how battery sizing is affected by battery siting and power flow simultaneity (PFS). This paper describes a method to compare the battery capacity required to provide grid services for different battery siting configurations and variable PFSs. The method was implemented by modelling a standard test grid with artificial power flow patterns and different battery siting configurations. The storage capacity of each configuration was minimised to determine how these variables affect the minimum storage capacity required to maintain power flows below a given threshold. In this case, a battery located at the transformer required 10–20% more capacity than a battery located centrally on the grid, or several batteries distributed throughout the grid, depending on PFS. The differences in capacity requirements were largely attributed to the ability of a BES configuration to mitigate network losses. The method presented in this paper can be used to compare BES capacity requirements for different battery siting configurations, power flow patterns, grid services, and grid characteristics.
Originele taal-2Engels
Artikelnummer7639
Aantal pagina's19
TijdschriftEnergies
Volume16
Nummer van het tijdschrift22
DOI's
StatusGepubliceerd - 2 nov. 2023

Financiering

This research was funded internally by the Hanze University of Applied Sciences.

Financiers
Hanze University of Applied Sciences

    Duurzame ontwikkelingsdoelstellingen van de VN

    Deze output draagt bij aan de volgende duurzame ontwikkelingsdoelstelling(en)

    1. SDG 7 – Betaalbare en schone energie
      SDG 7 – Betaalbare en schone energie

    Vingerafdruk

    Duik in de onderzoeksthema's van 'Sizing Batteries for Power Flow Management in Distribution Grids: A Method to Compare Battery Capacities for Different Siting Configurations and Variable Power Flow Simultaneity'. Samen vormen ze een unieke vingerafdruk.

    Citeer dit