Reproducing and improving one-dimensional convolutional neural networks for arterial blood pressure-based cardiac output estimation

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

Samenvatting

Cardiac output (CO) is an essential indicator of patient hemodynamic status. Monitoring of CO in the intensive care unit has been shown to improve perioperative outcomes by supporting patient fluid management. Arterial blood pressure-based cardiac output (APCO) estimation devices are minimally invasive compared to CO estimation using (transpulmonary) thermodilution, like the PiCCO system or the highly invasive gold standard method using the pulmonary artery catheter (PAC). However, inaccuracy in APCO device estimations during hemodynamically unstable periods, especially in vasodilatory situations, hamper their application in the critical care setting. An approach to improve APCO estimation involves utilizing a one-dimensional convolutional neural network (1D-CNN) to predict stroke volume (SV) from arterial blood pressure (ABP) and patient demographics. Previously published work demonstrated that by pre-training models on SV data from commercial APCO devices and adjusting them with transfer learning using SV data from the PAC, 1D-CNNs have superior performance over the in-use FloTrac APCO device. Preliminary results in the current study showed that by altering model training hyperparameters, model performance was improved further, significantly lowering the absolute error in PAC SV predictions of the original settings model from 13.9 (SD 11.6) mL to 11.7 (SD 11.0) mL for the new settings model (p < 0.001). This result shows promise in further improvement of deep learning-based APCO algorithms and the estimation of CO from ABP in the critical care setting.
Originele taal-2Engels
Titel2024 IEEE International Symposium on Medical Measurements and Applications (MeMeA)
UitgeverijInstitute of Electrical and Electronics Engineers
Aantal pagina's6
ISBN van elektronische versie979-8-3503-0799-3
ISBN van geprinte versie979-8-3503-0800-6
DOI's
StatusGepubliceerd - 29 jul. 2024
Evenement2024 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2024 - High Tech Campus, Eindhoven, Nederland
Duur: 26 jun. 202428 jun. 2024
https://memea2024.ieee-ims.org/

Congres

Congres2024 IEEE International Symposium on Medical Measurements and Applications, MeMeA 2024
Verkorte titelMeMeA 2024
Land/RegioNederland
StadEindhoven
Periode26/06/2428/06/24
Internet adres

Vingerafdruk

Duik in de onderzoeksthema's van 'Reproducing and improving one-dimensional convolutional neural networks for arterial blood pressure-based cardiac output estimation'. Samen vormen ze een unieke vingerafdruk.

Citeer dit