Photoacoustic perfusion measurements: a comparison with Power Doppler in phantoms

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

6 Downloads (Pure)

Uittreksel

Ultrasound-based measurements using Doppler, contrast, and more recently photoacoustics (PA), have emerged as techniques for tissue perfusion measurements. In this study, the feasibility of in vitro perfusion measurements with a fully integrated, hand-held, photoacoustic probe was investigated and compared to Power Doppler (PD). Three cylindrical polyvinyl alcohol (PVA) phantoms were made (diameter = 15 mm) containing 100, 200 and 400 parallel polysulfone tubes (diameter = 0.2 mm), resulting in a perfused cross-sectional area of 1.8, 3.6 and 7.1% respectively. Each phantom was perfused with porcine blood (15 mL/min). Cross-sectional PA images (λ = 805nm, frame rate = 10Hz) and PD images (PRF = 750Hz) were acquired with a MyLab One and MyLab 70 scanner (Esaote, NL), respectively. Data were averaged over 70 frames. The average PA signal intensity was calculated in a region-of-interest of 4 mm by 6 mm. The percentage of colored PD pixels was measured in the entire phantom region. The average signal intensity of the PA images increased linearly with perfusion density, being 0.54 (± 0.01), 0.56 (± 0.01), 0.58 (± 0.01) with an average background signal of 0.53 in the three phantoms, respectively. For PD, the percentage of colored pixels in the phantom area (1.5% (± 0.2%), 4.4% (± 0.2%), 13.7% (± 0.8%)) also increased linearly. The preliminary results suggest that PA, like PD, is capable of detecting an increase of blood volume in tissue. In the future, in vivo measurements will be explored, although validation will be more complex.

Originele taal-2Engels
TitelProgress in Biomedical Optics and Imaging
UitgeverijSPIE
Aantal pagina's4
ISBN van geprinte versie9781628414134
DOI's
StatusGepubliceerd - 2015
EvenementPhotons Plus Ultrasound: Imaging and Sensing 2015 - San Francisco, Verenigde Staten van Amerika
Duur: 8 feb 201510 feb 2015

Publicatie series

NaamProceedings of SPIE
Volume9323

Congres

CongresPhotons Plus Ultrasound: Imaging and Sensing 2015
LandVerenigde Staten van Amerika
StadSan Francisco
Periode8/02/1510/02/15

Vingerafdruk

Photoacoustic effect
Perfusion
Polyvinyl Alcohol
pixels
Blood Volume
blood volume
polyvinyl alcohol
Blood
Swine
Hand
Pixels
Tissue
scanners
blood
Polysulfones
Polyvinyl alcohols
tubes
probes
Ultrasonics

Citeer dit

Heres, H. M., Arabul, M., Tchang, B. C. Y., van de Vosse, F. N., Rutten, M. C. M., & Lopata, R. G. P. (2015). Photoacoustic perfusion measurements: a comparison with Power Doppler in phantoms. In Progress in Biomedical Optics and Imaging [932345] (Proceedings of SPIE; Vol. 9323). SPIE. https://doi.org/10.1117/12.2077556
Heres, H.M. ; Arabul, M. ; Tchang, B.C.Y. ; van de Vosse, F.N. ; Rutten, M.C.M. ; Lopata, R.G.P. / Photoacoustic perfusion measurements : a comparison with Power Doppler in phantoms. Progress in Biomedical Optics and Imaging. SPIE, 2015. (Proceedings of SPIE).
@inproceedings{3b4b61d38297472ebc0073807faaffae,
title = "Photoacoustic perfusion measurements: a comparison with Power Doppler in phantoms",
abstract = "Ultrasound-based measurements using Doppler, contrast, and more recently photoacoustics (PA), have emerged as techniques for tissue perfusion measurements. In this study, the feasibility of in vitro perfusion measurements with a fully integrated, hand-held, photoacoustic probe was investigated and compared to Power Doppler (PD). Three cylindrical polyvinyl alcohol (PVA) phantoms were made (diameter = 15 mm) containing 100, 200 and 400 parallel polysulfone tubes (diameter = 0.2 mm), resulting in a perfused cross-sectional area of 1.8, 3.6 and 7.1{\%} respectively. Each phantom was perfused with porcine blood (15 mL/min). Cross-sectional PA images (λ = 805nm, frame rate = 10Hz) and PD images (PRF = 750Hz) were acquired with a MyLab One and MyLab 70 scanner (Esaote, NL), respectively. Data were averaged over 70 frames. The average PA signal intensity was calculated in a region-of-interest of 4 mm by 6 mm. The percentage of colored PD pixels was measured in the entire phantom region. The average signal intensity of the PA images increased linearly with perfusion density, being 0.54 (± 0.01), 0.56 (± 0.01), 0.58 (± 0.01) with an average background signal of 0.53 in the three phantoms, respectively. For PD, the percentage of colored pixels in the phantom area (1.5{\%} (± 0.2{\%}), 4.4{\%} (± 0.2{\%}), 13.7{\%} (± 0.8{\%})) also increased linearly. The preliminary results suggest that PA, like PD, is capable of detecting an increase of blood volume in tissue. In the future, in vivo measurements will be explored, although validation will be more complex.",
keywords = "Perfusion, Phantom, Photoacoustic imaging, Power Doppler",
author = "H.M. Heres and M. Arabul and B.C.Y. Tchang and {van de Vosse}, F.N. and M.C.M. Rutten and R.G.P. Lopata",
year = "2015",
doi = "10.1117/12.2077556",
language = "English",
isbn = "9781628414134",
series = "Proceedings of SPIE",
publisher = "SPIE",
booktitle = "Progress in Biomedical Optics and Imaging",
address = "United States",

}

Heres, HM, Arabul, M, Tchang, BCY, van de Vosse, FN, Rutten, MCM & Lopata, RGP 2015, Photoacoustic perfusion measurements: a comparison with Power Doppler in phantoms. in Progress in Biomedical Optics and Imaging., 932345, Proceedings of SPIE, vol. 9323, SPIE, Photons Plus Ultrasound: Imaging and Sensing 2015, San Francisco, Verenigde Staten van Amerika, 8/02/15. https://doi.org/10.1117/12.2077556

Photoacoustic perfusion measurements : a comparison with Power Doppler in phantoms. / Heres, H.M.; Arabul, M.; Tchang, B.C.Y.; van de Vosse, F.N.; Rutten, M.C.M.; Lopata, R.G.P.

Progress in Biomedical Optics and Imaging. SPIE, 2015. 932345 (Proceedings of SPIE; Vol. 9323).

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

TY - GEN

T1 - Photoacoustic perfusion measurements

T2 - a comparison with Power Doppler in phantoms

AU - Heres, H.M.

AU - Arabul, M.

AU - Tchang, B.C.Y.

AU - van de Vosse, F.N.

AU - Rutten, M.C.M.

AU - Lopata, R.G.P.

PY - 2015

Y1 - 2015

N2 - Ultrasound-based measurements using Doppler, contrast, and more recently photoacoustics (PA), have emerged as techniques for tissue perfusion measurements. In this study, the feasibility of in vitro perfusion measurements with a fully integrated, hand-held, photoacoustic probe was investigated and compared to Power Doppler (PD). Three cylindrical polyvinyl alcohol (PVA) phantoms were made (diameter = 15 mm) containing 100, 200 and 400 parallel polysulfone tubes (diameter = 0.2 mm), resulting in a perfused cross-sectional area of 1.8, 3.6 and 7.1% respectively. Each phantom was perfused with porcine blood (15 mL/min). Cross-sectional PA images (λ = 805nm, frame rate = 10Hz) and PD images (PRF = 750Hz) were acquired with a MyLab One and MyLab 70 scanner (Esaote, NL), respectively. Data were averaged over 70 frames. The average PA signal intensity was calculated in a region-of-interest of 4 mm by 6 mm. The percentage of colored PD pixels was measured in the entire phantom region. The average signal intensity of the PA images increased linearly with perfusion density, being 0.54 (± 0.01), 0.56 (± 0.01), 0.58 (± 0.01) with an average background signal of 0.53 in the three phantoms, respectively. For PD, the percentage of colored pixels in the phantom area (1.5% (± 0.2%), 4.4% (± 0.2%), 13.7% (± 0.8%)) also increased linearly. The preliminary results suggest that PA, like PD, is capable of detecting an increase of blood volume in tissue. In the future, in vivo measurements will be explored, although validation will be more complex.

AB - Ultrasound-based measurements using Doppler, contrast, and more recently photoacoustics (PA), have emerged as techniques for tissue perfusion measurements. In this study, the feasibility of in vitro perfusion measurements with a fully integrated, hand-held, photoacoustic probe was investigated and compared to Power Doppler (PD). Three cylindrical polyvinyl alcohol (PVA) phantoms were made (diameter = 15 mm) containing 100, 200 and 400 parallel polysulfone tubes (diameter = 0.2 mm), resulting in a perfused cross-sectional area of 1.8, 3.6 and 7.1% respectively. Each phantom was perfused with porcine blood (15 mL/min). Cross-sectional PA images (λ = 805nm, frame rate = 10Hz) and PD images (PRF = 750Hz) were acquired with a MyLab One and MyLab 70 scanner (Esaote, NL), respectively. Data were averaged over 70 frames. The average PA signal intensity was calculated in a region-of-interest of 4 mm by 6 mm. The percentage of colored PD pixels was measured in the entire phantom region. The average signal intensity of the PA images increased linearly with perfusion density, being 0.54 (± 0.01), 0.56 (± 0.01), 0.58 (± 0.01) with an average background signal of 0.53 in the three phantoms, respectively. For PD, the percentage of colored pixels in the phantom area (1.5% (± 0.2%), 4.4% (± 0.2%), 13.7% (± 0.8%)) also increased linearly. The preliminary results suggest that PA, like PD, is capable of detecting an increase of blood volume in tissue. In the future, in vivo measurements will be explored, although validation will be more complex.

KW - Perfusion

KW - Phantom

KW - Photoacoustic imaging

KW - Power Doppler

UR - http://www.scopus.com/inward/record.url?scp=84928578365&partnerID=8YFLogxK

U2 - 10.1117/12.2077556

DO - 10.1117/12.2077556

M3 - Conference contribution

AN - SCOPUS:84928578365

SN - 9781628414134

T3 - Proceedings of SPIE

BT - Progress in Biomedical Optics and Imaging

PB - SPIE

ER -