Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise

H.M. Heres, T. Schoots, B.C.Y. Tchang, M.C.M. Rutten, H.M.C. Kemps, F.N. van de Vosse, R.G.P. Lopata

Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

Uittreksel

Purpose: Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated. Methods: Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. Results: A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2–0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18–60%). Conclusions: A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.

TaalEngels
Pagina's1209–1219
Aantal pagina's11
TijdschriftEuropean Journal of Applied Physiology
Volume118
Nummer van het tijdschrift6
DOI's
StatusGepubliceerd - 1 jun 2018

Vingerafdruk

Doppler Ultrasonography
Skeletal Muscle
Perfusion
Exercise
Muscles
Volunteers
Quadriceps Muscle
Exercise Test
Reproducibility of Results
Leg
Heart Failure

Citeer dit

@article{c5e88d617ecb4167bb9de44cfd23301b,
title = "Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise",
abstract = "Purpose: Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated. Methods: Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. Results: A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2–0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18–60{\%}). Conclusions: A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18{\%}) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.",
author = "H.M. Heres and T. Schoots and B.C.Y. Tchang and M.C.M. Rutten and H.M.C. Kemps and {van de Vosse}, F.N. and R.G.P. Lopata",
year = "2018",
month = "6",
day = "1",
doi = "10.1007/s00421-018-3850-y",
language = "English",
volume = "118",
pages = "1209–1219",
journal = "European Journal of Applied Physiology",
issn = "1439-6319",
publisher = "Springer",
number = "6",

}

Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise. / Heres, H.M.; Schoots, T.; Tchang, B.C.Y.; Rutten, M.C.M.; Kemps, H.M.C.; van de Vosse, F.N.; Lopata, R.G.P.

In: European Journal of Applied Physiology, Vol. 118, Nr. 6, 01.06.2018, blz. 1209–1219.

Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

TY - JOUR

T1 - Perfusion dynamics assessment with Power Doppler ultrasound in skeletal muscle during maximal and submaximal cycling exercise

AU - Heres,H.M.

AU - Schoots,T.

AU - Tchang,B.C.Y.

AU - Rutten,M.C.M.

AU - Kemps,H.M.C.

AU - van de Vosse,F.N.

AU - Lopata,R.G.P.

PY - 2018/6/1

Y1 - 2018/6/1

N2 - Purpose: Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated. Methods: Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. Results: A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2–0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18–60%). Conclusions: A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.

AB - Purpose: Assessment of limitations in the perfusion dynamics of skeletal muscle may provide insight in the pathophysiology of exercise intolerance in, e.g., heart failure patients. Power doppler ultrasound (PDUS) has been recognized as a sensitive tool for the detection of muscle blood flow. In this volunteer study (N = 30), a method is demonstrated for perfusion measurements in the vastus lateralis muscle, with PDUS, during standardized cycling exercise protocols, and the test–retest reliability has been investigated. Methods: Fixation of the ultrasound probe on the upper leg allowed for continuous PDUS measurements. Cycling exercise protocols included a submaximal and an incremental exercise to maximal power. The relative perfused area (RPA) was determined as a measure of perfusion. Absolute and relative reliability of RPA amplitude and kinetic parameters during exercise (onset, slope, maximum value) and recovery (overshoot, decay time constants) were investigated. Results: A RPA increase during exercise followed by a signal recovery was measured in all volunteers. Amplitudes and kinetic parameters during exercise and recovery showed poor to good relative reliability (ICC ranging from 0.2–0.8), and poor to moderate absolute reliability (coefficient of variation (CV) range 18–60%). Conclusions: A method has been demonstrated which allows for continuous (Power Doppler) ultrasonography and assessment of perfusion dynamics in skeletal muscle during exercise. The reliability of the RPA amplitudes and kinetics ranges from poor to good, while the reliability of the RPA increase in submaximal cycling (ICC = 0.8, CV = 18%) is promising for non-invasive clinical assessment of the muscle perfusion response to daily exercise.

UR - http://www.scopus.com/inward/record.url?scp=85044288254&partnerID=8YFLogxK

U2 - 10.1007/s00421-018-3850-y

DO - 10.1007/s00421-018-3850-y

M3 - Article

VL - 118

SP - 1209

EP - 1219

JO - European Journal of Applied Physiology

T2 - European Journal of Applied Physiology

JF - European Journal of Applied Physiology

SN - 1439-6319

IS - 6

ER -