Performance analysis of multirate systems: A direct frequency-domain identification approach

Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

5 Downloads (Pure)

Samenvatting

Frequency-domain performance analysis of intersample behavior in sampled-data and multirate systems is challenging due to the lack of a frequency-separation principle, and systematic identification techniques are lacking. The aim of this paper is to develop an efficient technique for identifying the full intersample performance in the frequency-domain for closed-loop multirate systems, in particular the Performance Frequency Gain (PFG). Through local modeling techniques, aliased frequency components are effectively disentangled when identifying the PFG, which is directly facilitated by frequency-lifting the multirate system to a multivariable time-invariant representation. The developed method accurately and directly identifies the PFG in a single identification experiment. Finally, the developed method is experimentally validated on a prototype motion system, showing accurate identification of frequency-domain representations for the multirate system, including the PFG.

Originele taal-2Engels
Artikelnummer112843
Aantal pagina's11
TijdschriftMechanical Systems and Signal Processing
Volume235
DOI's
StatusGepubliceerd - 15 jul. 2025

Bibliografische nota

Publisher Copyright:
© 2025 The Authors

Vingerafdruk

Duik in de onderzoeksthema's van 'Performance analysis of multirate systems: A direct frequency-domain identification approach'. Samen vormen ze een unieke vingerafdruk.

Citeer dit