A counterflow heat exchanger (CFHX) is an essential element for recuperative cooling cycles. The performance of the CFHX strongly influences the overall performance of the cryocooler. In the design of a heat exchanger, different loss mechanisms like pressure drop and parasitic heat flows are often treated sep. Acceptable values for the pressure drop and total heat leakage are estd. and thus a CFHX geometry is more or less arbitrarily chosen. This article applies another, less familiar design strategy where these losses are all treated as a prodn. of entropy. It is thus possible to compare and sum them. In this way, a CFHX configuration can be found that is optimal for a certain application, producing a min. of entropy and thus has min. losses. As an example, the design steps of a CFHX for the micro cooling project at the University of Twente are given. Also a generalization of micro CFHX dimensions for cooling powers between 10 and 120 mW is presented. [on SciFinder (R)]