Samenvatting
This paper describes the optimisation of the eddy current damping, applied in a passive tuned mass damper (TMD). A semi-analytical model based on scalar potential formulation is extended for different permanent magnet (PM) topologies. Optimal design parameters are acquired by particle swarm optimisation. A 3-DoF mechanical model is presented to predict the quality reduction factor of the TMD. Measurements are performed for validating the semi-analytical model. Furthermore, an experiment is carried out to test a TMD with two optimal PM topologies for sinusoidal excitations
Originele taal-2 | Engels |
---|---|
Pagina's (van-tot) | 641-648 |
Tijdschrift | IET Electric Power Applications |
Volume | 10 |
Nummer van het tijdschrift | 7 |
DOI's | |
Status | Gepubliceerd - 1 aug. 2016 |