Samenvatting
The performance of a process against voltage dips depends on the severity of voltage dips and the robustness of process equipment to voltage dips. This paper discusses about the performance of an AC contactor, one of the voltage sensitive equipment, against various types of voltage dips without and with mitigation techniques. First, lab tests are conducted to find the voltage-tolerance curves of the contactor without mitigation. Then, the tests are repeated with the AC-coil mitigated by Coil-Lock and phase-phase supply; and the tolerance curves of the device without and with mitigation are compared. To get better insight into the performance of the contactor, the severity of various types of voltage dips obtained from field measurements are compared with the voltage-tolerance curves of the contactor in both situations.
Originele taal-2 | Engels |
---|---|
Titel | 51st International Universities' Power Engineering Conference (UPEC), 6-9 September 2016, Coimbra, Portugal |
Plaats van productie | Piscataway |
Uitgeverij | Institute of Electrical and Electronics Engineers |
Pagina's | 1-6 |
Aantal pagina's | 6 |
ISBN van elektronische versie | 978-1-5090-4650-8 |
DOI's | |
Status | Gepubliceerd - 2 jul 2016 |
Evenement | 51th International Universities’ Power Engineering Conference (UPEC 2016) - Coimbra, Portugal Duur: 6 sep 2016 → 9 sep 2016 Congresnummer: 51 http://www.upec2016.com/ |
Congres
Congres | 51th International Universities’ Power Engineering Conference (UPEC 2016) |
---|---|
Verkorte titel | UPEC 2016 |
Land | Portugal |
Stad | Coimbra |
Periode | 6/09/16 → 9/09/16 |
Internet adres |