Samenvatting
This paper concerns the local reduction of the magnetic flux density by means of magnetic shielding. Using a spatial frequency description, a 2-D semi-analytical periodic model is obtained for a coreless single-sided linear permanent magnet motor. The magnetic shield is included in the modeling using mode-matching. The obtained magnetic flux density is compared to a finite element model and is verified with measurements. The results show a reasonable agreement between the semi- analytical model and the measurements. Some large deviations occur due to the
modeling assumption that the shield has a linear permeability, while the used shields are saturated. However, the semi-analytical modeling method is accurate enough for design purposes and initial calculations, especially when being aware of the possible saturation of the shield.
Originele taal-2 | Engels |
---|---|
Pagina's (van-tot) | 45-52 |
Aantal pagina's | 9 |
Tijdschrift | Applied Mechanics and Materials |
Volume | 416-417 |
DOI's | |
Status | Gepubliceerd - 2013 |