Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method

Evangelia Tourounoglou, Vasiliki Gkatsi, Anne Roc'h, Robert Vogt-Ardatjew, Hans Schipper, Frank Leferink

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

Uittreksel

The dual waveguide method for shielding effectiveness measurements is a very effective and practical method, as it can provide reliable results quickly and in a wide frequency range. However, when it comes to planar materials, the size and position of the sample is critical. Different sizes and shapes of the sample need to be tested in order to determine the one that provides reliable results. Furthermore, the position of the sample along the waveguide, as well as its distance from the source, using different lengths of waveguides, need to be investigated. In this paper, these two parameters are studied in order to examine their effect on the results.

Originele taal-2Engels
TitelEMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility
Plaats van productiePiscataway
UitgeverijInstitute of Electrical and Electronics Engineers
Pagina's707-711
Aantal pagina's5
ISBN van elektronische versie978-1-7281-0594-9
DOI's
StatusGepubliceerd - 1 sep 2019
Evenement2019 International Symposium on Electromagnetic Compatibility, EMC Europe 2019 - Barcelona, Spanje
Duur: 2 sep 20196 sep 2019

Congres

Congres2019 International Symposium on Electromagnetic Compatibility, EMC Europe 2019
LandSpanje
StadBarcelona
Periode2/09/196/09/19

Vingerafdruk

Shielding
shielding
Waveguides
waveguides
frequency ranges

Citeer dit

Tourounoglou, E., Gkatsi, V., Roc'h, A., Vogt-Ardatjew, R., Schipper, H., & Leferink, F. (2019). Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method. In EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility (blz. 707-711). [8871968] Piscataway: Institute of Electrical and Electronics Engineers. https://doi.org/10.1109/EMCEurope.2019.8871968
Tourounoglou, Evangelia ; Gkatsi, Vasiliki ; Roc'h, Anne ; Vogt-Ardatjew, Robert ; Schipper, Hans ; Leferink, Frank. / Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method. EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility. Piscataway : Institute of Electrical and Electronics Engineers, 2019. blz. 707-711
@inproceedings{fab239da43284eb28a684f256c78d2ae,
title = "Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method",
abstract = "The dual waveguide method for shielding effectiveness measurements is a very effective and practical method, as it can provide reliable results quickly and in a wide frequency range. However, when it comes to planar materials, the size and position of the sample is critical. Different sizes and shapes of the sample need to be tested in order to determine the one that provides reliable results. Furthermore, the position of the sample along the waveguide, as well as its distance from the source, using different lengths of waveguides, need to be investigated. In this paper, these two parameters are studied in order to examine their effect on the results.",
keywords = "dual waveguide, L-band waveguide, shielding effectiveness, shielding effectiveness material, X-band waveguide",
author = "Evangelia Tourounoglou and Vasiliki Gkatsi and Anne Roc'h and Robert Vogt-Ardatjew and Hans Schipper and Frank Leferink",
year = "2019",
month = "9",
day = "1",
doi = "10.1109/EMCEurope.2019.8871968",
language = "English",
pages = "707--711",
booktitle = "EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility",
publisher = "Institute of Electrical and Electronics Engineers",
address = "United States",

}

Tourounoglou, E, Gkatsi, V, Roc'h, A, Vogt-Ardatjew, R, Schipper, H & Leferink, F 2019, Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method. in EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility., 8871968, Institute of Electrical and Electronics Engineers, Piscataway, blz. 707-711, Barcelona, Spanje, 2/09/19. https://doi.org/10.1109/EMCEurope.2019.8871968

Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method. / Tourounoglou, Evangelia; Gkatsi, Vasiliki; Roc'h, Anne; Vogt-Ardatjew, Robert; Schipper, Hans; Leferink, Frank.

EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility. Piscataway : Institute of Electrical and Electronics Engineers, 2019. blz. 707-711 8871968.

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

TY - GEN

T1 - Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method

AU - Tourounoglou, Evangelia

AU - Gkatsi, Vasiliki

AU - Roc'h, Anne

AU - Vogt-Ardatjew, Robert

AU - Schipper, Hans

AU - Leferink, Frank

PY - 2019/9/1

Y1 - 2019/9/1

N2 - The dual waveguide method for shielding effectiveness measurements is a very effective and practical method, as it can provide reliable results quickly and in a wide frequency range. However, when it comes to planar materials, the size and position of the sample is critical. Different sizes and shapes of the sample need to be tested in order to determine the one that provides reliable results. Furthermore, the position of the sample along the waveguide, as well as its distance from the source, using different lengths of waveguides, need to be investigated. In this paper, these two parameters are studied in order to examine their effect on the results.

AB - The dual waveguide method for shielding effectiveness measurements is a very effective and practical method, as it can provide reliable results quickly and in a wide frequency range. However, when it comes to planar materials, the size and position of the sample is critical. Different sizes and shapes of the sample need to be tested in order to determine the one that provides reliable results. Furthermore, the position of the sample along the waveguide, as well as its distance from the source, using different lengths of waveguides, need to be investigated. In this paper, these two parameters are studied in order to examine their effect on the results.

KW - dual waveguide

KW - L-band waveguide

KW - shielding effectiveness

KW - shielding effectiveness material

KW - X-band waveguide

UR - http://www.scopus.com/inward/record.url?scp=85074336483&partnerID=8YFLogxK

U2 - 10.1109/EMCEurope.2019.8871968

DO - 10.1109/EMCEurope.2019.8871968

M3 - Conference contribution

AN - SCOPUS:85074336483

SP - 707

EP - 711

BT - EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility

PB - Institute of Electrical and Electronics Engineers

CY - Piscataway

ER -

Tourounoglou E, Gkatsi V, Roc'h A, Vogt-Ardatjew R, Schipper H, Leferink F. Influence of planar material size and position on shielding effectiveness measurements using the dual waveguide method. In EMC Europe 2019 - 2019 International Symposium on Electromagnetic Compatibility. Piscataway: Institute of Electrical and Electronics Engineers. 2019. blz. 707-711. 8871968 https://doi.org/10.1109/EMCEurope.2019.8871968