Samenvatting
Identifiability of linear dynamic networks typically depends on the presence and location of external (excitation or disturbance) signals, in relation to the topology of the parametrized network model set. For closed-loop identification, it is known that switching (non-parameterized) controllers can also provide excitation, thereby rendering the model set identifiable. In this paper, we derive verifiable conditions for network identifiability of the non-switching modules in presence of (non-parameterized) switching modules. These conditions generalize the classical result in closed-loop identification towards network identification. Furthermore, verifiable path-based conditions for identifiability in a generic sense are developed on the graph of the network model set.
Originele taal-2 | Engels |
---|---|
Pagina's (van-tot) | 37-42 |
Aantal pagina's | 6 |
Tijdschrift | IFAC-PapersOnLine |
Volume | 54 |
Nummer van het tijdschrift | 7 |
DOI's | |
Status | Gepubliceerd - jul. 2021 |
Evenement | 19th IFAC Symposium on System Identification (SYSID 2021) - Virtual, Padova, Italië Duur: 13 jul. 2021 → 16 jul. 2021 Congresnummer: 19 https://www.sysid2021.org/ |
Trefwoorden
- dynamic networks, system identication, switching systems, identiability