Samenvatting
We present laboratory measurements of dynamic permeability on samples consisting of capillary tubes. The dynamic permeability is a measure of the fluid flow response to an applied external oscillating pressure gradient such as exists in seismic waves. Existing theoretical models are validated. Moreover in our laboratory set-up also the Electrokinetic coupling is investigated. This coupling describes the fluid flow response to an external electric field such as exists in recent field tests where a high-voltage sources ...
Originele taal-2 | Engels |
---|---|
Titel | Expanded abstracts of the 69th EAGE Conference & Exhibition incorporating SPE EUROPEC 2007, 11-14 June 2007, London, United Kingdom |
Pagina's | P018-1/5 |
Status | Gepubliceerd - 2007 |