TY - JOUR
T1 - Easy Integrability and Data Processing of a Soft Tactile Array Sensor Through Reconfiguration
AU - Legrand, Julie
AU - Roels, Ellen
AU - Vanderborght, Bram
PY - 2023/4/1
Y1 - 2023/4/1
N2 - Most soft tactile sensors require a large number of wires to read the sensed data and complex algorithms to treat them. This makes the integration of soft tactile sensors challenging in full robotic systems. In order to simplify the integration of those soft devices, a new type of soft tactile array sensor is proposed. The sensitive keys of the sensor are made of three different self-healing Diels–Alder (DA) conductive polymers. The key positions in the sensor array are optimized in order to maximize the sensor accuracy in detecting pressed key positions and limit the number of wires required to read the sensor data. Since DA polymers are used, the keys are robustly connected to each other, ensuring high interfacial strength and conductivity while allowing reconfiguration. The reversible covalent bonds of the DA polymer allow the keys to be cut and healed back together to reform another tactile sensor tailored for another application with full recovery of the initial mechanical and electrical properties. In this work, two study cases are investigated: a keypad and a position sensor. The novel soft tactile array could reach an accuracy as low as 1.31% for the keypad and 3.8% for the position sensor compared with the developed sensor model. The keypad has a 90% success rate, whereas the position sensor has a 64% success rate.
AB - Most soft tactile sensors require a large number of wires to read the sensed data and complex algorithms to treat them. This makes the integration of soft tactile sensors challenging in full robotic systems. In order to simplify the integration of those soft devices, a new type of soft tactile array sensor is proposed. The sensitive keys of the sensor are made of three different self-healing Diels–Alder (DA) conductive polymers. The key positions in the sensor array are optimized in order to maximize the sensor accuracy in detecting pressed key positions and limit the number of wires required to read the sensor data. Since DA polymers are used, the keys are robustly connected to each other, ensuring high interfacial strength and conductivity while allowing reconfiguration. The reversible covalent bonds of the DA polymer allow the keys to be cut and healed back together to reform another tactile sensor tailored for another application with full recovery of the initial mechanical and electrical properties. In this work, two study cases are investigated: a keypad and a position sensor. The novel soft tactile array could reach an accuracy as low as 1.31% for the keypad and 3.8% for the position sensor compared with the developed sensor model. The keypad has a 90% success rate, whereas the position sensor has a 64% success rate.
KW - Self-healing material
KW - soft robotic interface
KW - soft sensor
KW - touch sensor
UR - http://www.scopus.com/inward/record.url?scp=85149828306&partnerID=8YFLogxK
U2 - 10.1109/JSEN.2023.3250947
DO - 10.1109/JSEN.2023.3250947
M3 - Article
SN - 1530-437X
VL - 23
SP - 7719
EP - 7727
JO - IEEE Sensors Journal
JF - IEEE Sensors Journal
IS - 7
ER -