    Samenvatting

    A method is presented to rapidly characterize the hermeticity of a vacuum cavity for a high frequency (omega(0)/(2 pi)= 56 MHz) micromechanical bulk-wave resonator. The method relies on operating the device in a low-stiffness out-of-plane resonance mode. By monitoring the Q-factor and resonance frequency shift of this out-of-plane mode, the pressure change inside the cavity can be measured with a sensitivity that is 100-1000 times higher than when using the functional bulk mode. This high sensitivity pressure sensing is vital for estimating the life-time of vacuum packaged resonators within a limited test-time. The experimental results are well described by the squeeze-film damping model of Suijlen et al. [27] and the classical predictions for kinetic damping and drag forces based on gas kinetic theory, within the experimental error of 15% for Q and 3% for Delta omega(0). For this purpose the model has been extended to include the effect of coupled squeeze-film boxes, which can be expressed in terms of an effective gap height and an effective escape time. (C) 2011 Elsevier B.V. All rights reserved
    Originele taal-2Engels
    Pagina's (van-tot)139-149
    Aantal pagina's11
    TijdschriftSensors and Actuators, A: Physical
    Volume175
    DOI's
    StatusGepubliceerd - 2012