Samenvatting
The Advanced Continuous-wave Electron (ACE) injector group at the Coherence and Quantum Technology (CQT) group of the Eindhoven University of Technology is developing a GHz repetition-rate electron injector where a low emittance and high repetition-rate are simultaneously required. The injector is based on a high-quality DC thermionic gun and two normal conducting RF cavities utilizing dual-mode resonance frequencies in the 1.5–3 GHz range. In the first phase, the installation and commissioning of ACE's electron gun were completed. In this next phase, two dual modes RF cavities are designed for chopping and compressing of a DC electron beam. This paper focuses on the RF design and measurements of these cavities, demonstrating the claimed quality and performance.
| Originele taal-2 | Engels |
|---|---|
| Artikelnummer | 165843 |
| Tijdschrift | Nuclear Instruments and Methods in Physics Research. Section A: Accelerators, Spectrometers, Detectors and Associated Equipment |
| Volume | 1019 |
| DOI's | |
| Status | Gepubliceerd - 11 dec. 2021 |
Bibliografische nota
Publisher Copyright:© 2021 The Author(s)
Financiering
The authors would like to thank Eddy Rietman and Harry van Doorn for their invaluable technical support in the mechanical and electrical design of the thermionic gun. This research is part of the High Tech Systems and Materials programme of the Netherlands Organization for Scientific Research (NWO-AES) and is supported by ASML, Netherlands .