TY - JOUR
T1 - Composition dependent mechanical behaviour of S53P4 bioactive glass putty for bone defect grafting
AU - van Gestel, N.A.P.
AU - Hulsen, D.J.W.
AU - Geurts, J.A.P.
AU - Hofmann, S.
AU - Ito, K.
AU - Arts, J.J.C.
AU - van Rietbergen, B.
PY - 2017/5/1
Y1 - 2017/5/1
N2 - To improve the handling properties of S53P4 bioactive glass granules for clinical applications, bioactive glass putty formulations were developed. These formulations contain both granules and a synthetic binder to form an injectable material that is easy to shape. To explore its applicability in load-bearing bone defect grafting, the relation between the putty composition and its mechanical behaviour was assessed in this study. Five putty formulations with variations in synthetic binder and granule content were mechanically tested in confined compression. The results showed that the impaction strains significantly decreased and the residual strains significantly increased with an increasing binder content. The stiffness of all tested formulations was found to be in the same range as the reported stiffness of cancellous bone. The measured creep strains were low and no significant differences between formulations were observed. The stiffness significantly increased when the samples were subjected to a second loading stage. The residual strains calculated from this second loading stage were also significantly different from the first loading stage, showing an increasing difference with an increasing binder content. Since residual strains are detrimental for graft layer stability in load-bearing defects, putty compositions with a low binder content would be most beneficial for confined, load-bearing bone defect grafting.
AB - To improve the handling properties of S53P4 bioactive glass granules for clinical applications, bioactive glass putty formulations were developed. These formulations contain both granules and a synthetic binder to form an injectable material that is easy to shape. To explore its applicability in load-bearing bone defect grafting, the relation between the putty composition and its mechanical behaviour was assessed in this study. Five putty formulations with variations in synthetic binder and granule content were mechanically tested in confined compression. The results showed that the impaction strains significantly decreased and the residual strains significantly increased with an increasing binder content. The stiffness of all tested formulations was found to be in the same range as the reported stiffness of cancellous bone. The measured creep strains were low and no significant differences between formulations were observed. The stiffness significantly increased when the samples were subjected to a second loading stage. The residual strains calculated from this second loading stage were also significantly different from the first loading stage, showing an increasing difference with an increasing binder content. Since residual strains are detrimental for graft layer stability in load-bearing defects, putty compositions with a low binder content would be most beneficial for confined, load-bearing bone defect grafting.
KW - Bioactive glass
KW - Confined compression
KW - Load-bearing bone defect grafting
KW - Micro computed tomography
KW - Putty
UR - http://www.scopus.com/inward/record.url?scp=85010304294&partnerID=8YFLogxK
U2 - 10.1016/j.jmbbm.2017.01.024
DO - 10.1016/j.jmbbm.2017.01.024
M3 - Article
C2 - 28131065
SN - 1751-6161
VL - 69
SP - 301
EP - 306
JO - Journal of the Mechanical Behavior of Biomedical Materials
JF - Journal of the Mechanical Behavior of Biomedical Materials
ER -