Bearing capacity of bolt washers

A.J.M. Leijten, A.J.M. Jorissen

Onderzoeksoutput: Hoofdstuk in Boek/Rapport/CongresprocedureConferentiebijdrageAcademicpeer review

2 Downloads (Pure)

Samenvatting

The European Yield Model (EYM) has been accepted to determine the load-carrying capacity of structural timber connections. However, experiments of bolted connections are still not in agreement with the EYM unless the additional bearing capacity offered by the washers is taken into account. This bearing capacity is depending on the compressive strength perpendicular to grain of the structural timber. Tests results carried out with M16 and M24 washers on solid and glued laminated timber are used to verify the reliability of three strength capacity predicting models, one of which is an analytical model while the other two are empirical. It was concluded that the analytical model is the superior one. This model should be incorporated in all new structural timber design code revisions..
Originele taal-2Engels
TitelProceedings of the World Conference on Timber Engineering, Trento, June 2010
RedacteurenA. Ceccotti, J-W. Van de Kuilen
Plaats van productieTrento
UitgeverijCNR-IVALSA
Pagina's1-6
StatusGepubliceerd - 2010
Evenement2010 World Conference on Timber Engineering (WCTE 2010) - trento, Italië
Duur: 21 jun. 201024 jun. 2010
Congresnummer: 11

Congres

Congres2010 World Conference on Timber Engineering (WCTE 2010)
Verkorte titelWCTE 2010
Land/RegioItalië
Stadtrento
Periode21/06/1024/06/10
AnderWorld Conference on Timber Engineering (WCTE)

Vingerafdruk

Duik in de onderzoeksthema's van 'Bearing capacity of bolt washers'. Samen vormen ze een unieke vingerafdruk.

Citeer dit