Samenvatting
An automatic method for delineating the prostate (including the seminal vesicles) in three-dimensional magnetic resonance scans is presented. The method is based on nonrigid registration of a set of prelabeled atlas images. Each atlas image is nonrigidly registered with the target patient image. Subsequently, the deformed atlas label images are fused to yield a single segmentation of the patient image. The proposed method is evaluated on 50 clinical scans, which were manually segmented by three experts. The Dice similarity coefficient (DSC) is used to quantify the overlap between the automatic and manual segmentations. We investigate the impact of several factors on the performance of the segmentation method. For the registration, two similarity measures are compared: Mutual information and a localized version of mutual information. The latter turns out to be superior (median ¿DSC˜0.02, p0.05). To assess the influence of the atlas composition, two atlas sets are compared. The first set consists of 38 scans of healthy volunteers. The second set is constructed by a leave-one-out approach using the 50 clinical scans that are used for evaluation. The second atlas set gives substantially better performance (¿DSC=0.04,p
Originele taal-2 | Engels |
---|---|
Pagina's (van-tot) | 1407-1417 |
Tijdschrift | Medical Physics |
Volume | 35 |
Nummer van het tijdschrift | 4 |
DOI's | |
Status | Gepubliceerd - 2008 |