T1 - Attenuated cardiac function degradation in ex vivo pig hearts
AU - Kappler, Benjamin
AU - van Tuijl, Sjoerd
AU - Ergin, Bülent
AU - Fixsen, Louis
AU - Stijnen, Marco
AU - Ince, Can
AU - de Mol, Bas A.J.M.
PY - 2020/3/1
Y1 - 2020/3/1
N2 - Isolated hearts offer the opportunity to evaluate heart function, treatments, and diagnostic tools without in vivo factor interference. However, the early loss of cardiac function and edema occur over time and do limit the duration of the experiment. This research focuses on delaying these limitations using optimal blood control. This study examines whether blood conditioning by means of the combination of blood predilution and hemodialysis can significantly reduce cardiac function degradation. Slaughterhouse porcine hearts were revived in the PhysioHeart™ platform to restore physiological cardiac performance. Twelve hearts were divided into a control group and a dialysis group; in the latter group, hemodialysis was attached to the blood reservoir. Cardiac hemodynamics and blood parameters were recorded and evaluated. Blood conditioning significantly reduced the loss of cardiac pump function (control group vs dialysis group, −14.9 ± 6.3%/h vs −9.7 ± 2.7%/h) and loss of cardiac output (control group vs dialysis group, −11.8 ± 3.4%/h vs −5.9 ± 2.0%/h). Hemodialysis resulted in physiological and stable blood parameters, whereas in the control group ions reached pathological values, while interstitial edema still occurred. The combination of blood predilution and hemodialysis significantly attenuated ex vivo cardiac function degradation and delayed the loss of cardiac hemodynamics. We hypothesized that besides electrolyte and metabolic control, the hemodialysis-accompanied increase in hematocrit resulted in improved oxygen transport. This could have temporarily compensated the deleterious effect of an increased oxygen-diffusion distance due to edema in the dialysis group and resulted in less progression of cell decay. Clinically validated measures delaying edema might improve the effectiveness of the PhysioHeart™ platform.
AB - Isolated hearts offer the opportunity to evaluate heart function, treatments, and diagnostic tools without in vivo factor interference. However, the early loss of cardiac function and edema occur over time and do limit the duration of the experiment. This research focuses on delaying these limitations using optimal blood control. This study examines whether blood conditioning by means of the combination of blood predilution and hemodialysis can significantly reduce cardiac function degradation. Slaughterhouse porcine hearts were revived in the PhysioHeart™ platform to restore physiological cardiac performance. Twelve hearts were divided into a control group and a dialysis group; in the latter group, hemodialysis was attached to the blood reservoir. Cardiac hemodynamics and blood parameters were recorded and evaluated. Blood conditioning significantly reduced the loss of cardiac pump function (control group vs dialysis group, −14.9 ± 6.3%/h vs −9.7 ± 2.7%/h) and loss of cardiac output (control group vs dialysis group, −11.8 ± 3.4%/h vs −5.9 ± 2.0%/h). Hemodialysis resulted in physiological and stable blood parameters, whereas in the control group ions reached pathological values, while interstitial edema still occurred. The combination of blood predilution and hemodialysis significantly attenuated ex vivo cardiac function degradation and delayed the loss of cardiac hemodynamics. We hypothesized that besides electrolyte and metabolic control, the hemodialysis-accompanied increase in hematocrit resulted in improved oxygen transport. This could have temporarily compensated the deleterious effect of an increased oxygen-diffusion distance due to edema in the dialysis group and resulted in less progression of cell decay. Clinically validated measures delaying edema might improve the effectiveness of the PhysioHeart™ platform.
KW - cardiac hemoperfusion
KW - Ex vivo
KW - hemodialysis
UR - http://www.scopus.com/inward/record.url?scp=85074333367&partnerID=8YFLogxK
U2 - 10.1177/0391398819879706
DO - 10.1177/0391398819879706
M3 - Article
C2 - 31621467
AN - SCOPUS:85074333367
SN - 0391-3988
VL - 43
SP - 173
EP - 179
JO - International Journal of Artificial Organs
JF - International Journal of Artificial Organs
IS - 3
ER -