The sampling nature of the phase-frequency detector (PFD) degrades the stability of the charge-pump phase-locked loop (CPPLL). This paper analyzes the effect of the PFD sampling on the CPPLL stability by using z-transform. The PFD is modeled as a zero-order hold to perform the z-domain analysis. The stability boundary predicted by the analysis is accurate and verified by simulations using Cadence Spectre. In addition, a physical interpretation of how sampling destabilizes an otherwise stable continuous feedback system is provided in time domain, which brings valuable insight into the operation of sampled feedback systems like CPPLL.