Doorgaan naar hoofdnavigatie Doorgaan naar zoeken Ga verder naar hoofdinhoud

An improved method to measure transfer functions using MRI

Onderzoeksoutput: Bijdrage aan tijdschriftTijdschriftartikelAcademicpeer review

30 Downloads (Pure)

Samenvatting

Purpose: A previously published method for MRI-based transfer function assessment makes use of the so-called transceive phase assumption (TPA). This limits its applicability to shorter leads and/or lower field strengths. A new method is presented where the background electric field is determined from both (Formula presented.) - and (Formula presented.) -field distributions, avoiding the TPA and making it more generally applicable. Theory and Methods: These (Formula presented.) -distributions are determined from a spoiled gradient echo multiflip angle acquisition. From the separated (Formula presented.) -components the background electrical field and the induced current are computed. Further improvement is achieved by recasting the (Formula presented.) -field model as a “magnitude squared least squares” problem. The proposed reconstruction method is used to determine transfer functions of various copper wire lengths up to 40 cm inside an elliptical ASTM phantom. The method is first tested on EM-simulated data and subsequently phantom and bench measurements are used to determine transfer functions experimentally. Results: In silica reconstructions demonstrate the validity of the proposed (Formula presented.) -field model resulting in highly accurate reconstructed (Formula presented.) -fields, currents, incident electric fields and transfer functions. The experimental results show slight deviations in the field model, however, resulting transfer functions are accurately determined with high similarity to simulations and comparable to bench measurements. Conclusion: A more generally applicable method for MRI-based transfer function assessment is presented. The proposed method circumvents phase assumptions making it applicable for longer objects and/or higher field strengths. Additional improvements are implemented in the (Formula presented.) -mapping method and the solution algorithm.

Originele taal-2Engels
Pagina's (van-tot)2246-2260
Aantal pagina's15
TijdschriftMagnetic Resonance in Medicine
Volume92
Nummer van het tijdschrift5
DOI's
StatusGepubliceerd - nov. 2024

Bibliografische nota

Publisher Copyright:
© 2024 International Society for Magnetic Resonance in Medicine.

Vingerafdruk

Duik in de onderzoeksthema's van 'An improved method to measure transfer functions using MRI'. Samen vormen ze een unieke vingerafdruk.

Citeer dit