Abstract
The energy and volume consumption of a hybrid membrane system with a Condensed Rotational Separation distillation process on the permeate gas stream of the membrane is analyzed and compared with a hybrid amine – CRS process. Both energy and volume use can be reduced by at least a factor 2.
Original language | English |
---|---|
Pages (from-to) | 874-876 |
Journal | Energy Technology |
Volume | 2 |
Issue number | 11 |
DOIs | |
Publication status | Published - 2014 |