The Real Time Mass Evaluation System as a tool for the detection of undeclared cascade operation at GCEPs

J.F.A. Delbeke, J. Howell, G. Eklund, G. Janssens-Maenhout, P. Peerani, W. Janssens

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Abstract

Given the flexibility of current cascade designs a real time mass monitoring system is preferred for safeguarding Gas Centrifuge Enrichment Plants. However, if such a system is to be installed in a GCEP it must not impinge on plant operation or be intrusive. Since load cells are already part of the operational process and located outside the cascade hall their exploitation for safeguards purposes is an obvious development. The paper describes, through dynamic simulations, how transients would be observed in real-time mass balances when undeclared cascade operation takes place in a declared facility.
Original languageEnglish
Title of host publicationProceedings of the 8th International Conference on Facility Operations-Safeguards Interface, 30 March - 4 April 2008, Portland Oregon
Publication statusPublished - 2008
Externally publishedYes

Fingerprint Dive into the research topics of 'The Real Time Mass Evaluation System as a tool for the detection of undeclared cascade operation at GCEPs'. Together they form a unique fingerprint.