Skip to main navigation Skip to search Skip to main content

The main gap discharge types and mechanism of a triggered vacuum gap

  • W. Shang
  • , G.C. Damstra

Research output: Chapter in Book/Report/Conference proceedingConference contributionAcademicpeer-review

Abstract

In the positive mode of triggered vacuum gaps, the discharge has three different types: sustained breakdown without chopping (SB); sustained breakdown with chopping (SBC); and nonsustained breakdown with chopping (NSBC). In the negative mode, only sustained breakdown occurs. The influence of main gap voltage, residual gas pressure and the trigger type have been investigated based on the type of main gap discharge. It is shown that the type of main gap discharge has a statistical property. Finally, the discharge mechanism is discussed based on the trigger plasma property.
Original languageEnglish
Title of host publication17th International Symposium on Discharges and Electrical Insulation in Vacuum
Place of PublicationPiscataway
PublisherInstitute of Electrical and Electronics Engineers
Pages51-55
Volume1
ISBN (Print)0-7803-2906-6
DOIs
Publication statusPublished - 1996
Event17th International Symposium on Discharges and Electrical Insulation in Vacuum - Berkeley, United States
Duration: 21 Jul 199626 Jul 1996

Conference

Conference17th International Symposium on Discharges and Electrical Insulation in Vacuum
Country/TerritoryUnited States
CityBerkeley
Period21/07/9626/07/96

Fingerprint

Dive into the research topics of 'The main gap discharge types and mechanism of a triggered vacuum gap'. Together they form a unique fingerprint.

Cite this