The influence of lesion location on the diagnostic accuracy of adenosine-free coronary pressure wire measurements

  • Yuhei Kobayashi
  • , Nils P. Johnson
  • , Colin Berry
  • , Bernard De Bruyne
  • , K. Lance Gould
  • , Allen Jeremias
  • , Keith G. Oldroyd
  • , Nico H.J. Pijls
  • , William F. Fearon

Research output: Contribution to journal › Article › Academic › peer-review

Abstract

Objectives This work compares the diagnostic performance of adenosine-free coronary pressure wire indices based on lesion location. Background Several adenosine-free coronary pressure wire indices have been proposed to assess the functional significance of coronary artery lesions; however, there is a theoretical concern that lesion location and the mass of perfused myocardium may affect diagnostic performance. Methods A total of 763 patients were prospectively enrolled from 12 institutions. Fractional flow reserve (FFR) and contrast-based FFR (cFFR) were obtained during adenosine-induced maximal hyperemia and contrast-induced submaximal hyperemia respectively, whereas the instantaneous wave-free ratio (iFR) and distal pressure/aortic pressure (Pd/Pa) were obtained at rest. Using an FFR of ≤0.80 as a reference standard, the diagnostic accuracy of each index was compared based on lesion location (left main or proximal left anterior descending artery [LM/pLAD] compared with other lesion locations). Results The median FFR, cFFR, iFR, and Pd/Pa were 0.81 (interquartile range [IQR]: 0.74 to 0.87), 0.86 (IQR: 0.79 to 0.91), 0.90 (IQR: 0.85 to 0.94), and 0.92 (IQR: 0.88 to 0.95), respectively. The cFFR, iFR, and Pd/Pa were less accurate in LM/pLAD compared with other lesion locations (cFFR: 80.3% vs. 87.8%; iFR: 73.3% vs. 81.8%; Pd/Pa: 71.4% vs. 81.1%, respectively). By receiver-operating characteristics curve analysis, cFFR provided better diagnostic accuracy than resting indices regardless of lesion location (p ≤0.0001 vs. iFR and Pd/Pa for both groups). Conclusions The cFFR, iFR, and Pd/Pa are less accurate in LM/pLAD compared with other lesion locations, likely related to the larger amount of myocardium supplied by LM/pLAD. Nevertheless, cFFR provides the best diagnostic accuracy among the adenosine-free indices, regardless of lesion location.

Original languageEnglish
Pages (from-to)2390-2399
Number of pages10
JournalJACC: Cardiovascular Interventions
Volume9
Issue number23
DOIs
Publication statusPublished - 12 Dec 2016

Keywords

  • contrast fractional flow reserve
  • fractional flow reserve
  • instantaneous wave-free ratio

Fingerprint

Dive into the research topics of 'The influence of lesion location on the diagnostic accuracy of adenosine-free coronary pressure wire measurements'. Together they form a unique fingerprint.

Cite this