Skip to main navigation Skip to search Skip to main content

The effect of HydroSpacer implant placement on the wear of opposing and adjacent cartilage

Research output: Contribution to journalArticleAcademicpeer-review

108 Downloads (Pure)

Abstract

A HydroSpacer implant, that is, a swelling hydrogel confined by a spacer fabric, was developed to repair focal cartilage defects and to prevent progression into osteoarthritis. The present study evaluated the effect of implant placement height in an osteochondral (OC) plug on wear of the opposing and adjacent cartilage. Three-dimensional warp-knitted spacer fabrics, polycaprolactone with poly(4-hydroxybutyrate) pile yarns, were filled with a hyaluronic acid methacrylate and chondroitin sulfate methacrylate hydrogel. After polymerization of the hydrogel, these HydroSpacers were implanted in OC defects (ø 6 mm) created in bovine OC plugs (ø 10 mm) and allowed to swell to equilibrium. A custom-made pin-on-plate wear apparatus was used to apply simultaneous compression and sliding against bovine cartilage. Cartilage damage, visualized with Indian ink, was only seen for the group in which the HydroSpacer was placed flush with the surrounding cartilage. A significant increase on average surface roughness of the sliding path compared to the adjacent cartilage confirmed surface damage for this group. When the implants were recessed (with and without extra hydrogel layer on top of the implant), this damage was not observed, but the cartilage surrounding the implants was compressed (without damage) indicating substantial load sharing with the implant. Furthermore, it was shown that all defects treated with a HydroSpacer implant resulted in shear forces comparable to intact cartilage. Clinical significance: The present study suggests that placing a HydroSpacer implant recessed into the surrounding cartilage would decrease wear of the opposing cartilage. Altogether, this study supports the development of textile-constraining hydrogels for cartilage replacement.

Original languageEnglish
Pages (from-to)1397-1406
Number of pages10
JournalJournal of Orthopaedic Research
Volume41
Issue number7
DOIs
Publication statusPublished - Jul 2023

Funding

This work was supported by the framework of Chemelot InSciTe, supported by the partners of Regenerative Medicine Crossing Borders and powered by Health~Holland, Top Sector Life Sciences & Health. We acknowledge Kai-Chieh Kuo (ITA Institut für Textiltechnik, RWTH Aachen University) for producing the spacer fabrics and Marko Mihajlovic (Utrecht Institute for Pharmaceutical Sciences, Utrecht University) for producing the hydrogel. We are grateful to Jurgen Bulsink for his assistance in developing the test setup.

Funders
Utrecht University
RWTH Aachen University

    Keywords

    • articular cartilage
    • osteoarthritis
    • resurfacing implant
    • textile
    • wear
    • Hydrogels
    • Cartilage Diseases
    • Humans
    • Cartilage, Articular/surgery
    • Prostheses and Implants
    • Animals
    • Cattle
    • Osteoarthritis

    Fingerprint

    Dive into the research topics of 'The effect of HydroSpacer implant placement on the wear of opposing and adjacent cartilage'. Together they form a unique fingerprint.

    Cite this